7.2.  Scan Area and Resolution 
The depth of field is measured from the edge of the scanner. The scanning range is 
within the circular arc centered on the scan origin.  
 
Figure 3: Scan area and resolution (in mm) 
 
Resolution Symbology 
PCS 
Quiet 
Zone 
Digit 
Decode 
depth (mm) 
1.0 mm 
CODE-39 
0.9 
25 mm 
1  
30 - 590 
0.5 mm  
CODE-39 
0.9 
18 mm 
3  
10 - 360 
0.25 mm 
CODE-39 
0.9 
10 mm 
8  
10 - 200 
0.15 mm 
CODE-39 
0.9 
 7 mm 
10  
10 - 90 
0.127 mm 
CODE-39 
0.9 
 5 mm 
4  
20 - 60 
Conditions: 
Barcode Sample: OPTOELECTRONICS Test Sample 
N/W Ratio: 
1:2.5 
Angle: 
α = 0°, β = 15°, γ = 0° 
Curvature: 
R = ∞