Opticon LMD 1135 Benutzerhandbuch

Seite von 73
Manual No. 25-ULPNR102-01; Mar, 2005                                   LMD 1135 Laser Fixed Mount Scanner 
Page  64 
 
34. Redundant Decoding 
The Number of Redundant Decodes determines how many times the scanner must decode a bar code 
and obtain the same value before it will transmit the data.  For example, if the redundancy is set at three 
times, the scanner will not transmit data until it has completed three consecutive, identical  “good reads”.   
In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans 
where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth 
scan.  In other words, a “no decode” does not restart the sequence.   
 
Computer 
Command 
Function 
/Description 
Bar Code 
Command 
 
(ZZ) 
START/END  
Programming Menu 
 [[ 
X0 
Read bar code once  
 Y1 
X1 
Read bar code twice 
 Y2 
X2 
Read bar code three times 
 Y3  %
X3 
Read bar code four times 
 Y! 
BS 
Read bar code five times 
 CT 
BT 
Read bar code six times 
 CU 
BU 
Read bar code seven times 
 CV 
BV 
Read bar code eight times 
 CW 
BW 
Read bar code nine times 
 CX