MULTIPLE-PROCESSOR MANAGEMENT
Software must not assume local APIC_ID values in an MP system are consecutive. 
Non-consecutive local APIC_IDs may be the result of hardware configurations or 
debug features implemented in the BIOS or OS.
An identifier for each hierarchical level can be extracted from an 8-bit APIC_ID using 
the support routines illustrated in Example 8-20. The appropriate bit mask and shift 
value to construct the appropriate bit mask for each level must be determined 
dynamically at runtime. 
8.9.5 
Identifying Topological Relationships in a MP System
To detect the number of physical packages, processor cores, or other topological 
relationships in a MP system, the following procedures are recommended:
Extract the three-level identifiers from the APIC ID of each logical processor 
enabled by system software. The sequence is as follows (See the pseudo code 
shown in Example 8-21 and support routines shown in Example 8-18):
The extraction start from the right-most bit field, corresponding to 
SMT_ID, the innermost hierarchy in a three-level topology (See Figure 
8-7
). For the right-most bit field, the shift value of the working mask is 
zero. The width of the bit field is determined dynamically using the 
maximum number of logical processor per core, which can be derived 
from information provided from CPUID.
To extract the next bit-field, the shift value of the working mask is 
determined from the width of the bit mask of the previous step. The width 
of the bit field is determined dynamically using the maximum number of 
cores per package.
To extract the remaining bit-field, the shift value of the working mask is 
determined from the maximum number of logical processor per package. 
So the remaining bits in the APIC ID (excluding those bits already 
extracted in the two previous steps) are extracted as the third identifier. 
This applies to a non-clustered MP system, or if there is no need to 
distinguish between PACKAGE_ID and CLUSTER_ID.
If there is need to distinguish between PACKAGE_ID and CLUSTER_ID, 
PACKAGE_ID can be extracted using an algorithm similar to the 
extraction of CORE_ID, assuming the number of physical packages in 
each node of a clustered system is symmetric.
Assemble the three-level identifiers of SMT_ID, CORE_ID, PACKAGE_IDs into 
arrays for each enabled logical processor. This is shown in Example 8-22a.
To detect the number of physical packages: use PACKAGE_ID to identify those 
logical processors that reside in the same physical package. This is shown in 
Example 8-22b. This example also depicts a technique to construct a mask to 
represent the logical processors that reside in the same package.
To detect the number of processor cores: use CORE_ID to identify those logical 
processors that reside in the same core. This is shown in Example 8-22. This