Panasonic AWHE60SN Benutzerhandbuch

Seite von 114
84
Controls and settings from web screen
(continued)
p
qUser mng.
The authorization of those users who can access the camera from a personal computer or AW-RP50 and those IP addresses, 
from which the camera can be accessed, is registered on this screen in order to restrict any other access.
The screen itself consists of three tabs, “User auth.”, “Host auth” and “Priority Stream”.
User auth. screen
  User auth.
<Initial setting: Off>
User authorization is set to “On” or “Off” here.
Enter the setting using the Set button.
  User name [1 to 32 half‑size characters]
<Initial setting: blank>
The user name is input here.
Enter the setting using the Set button.
  Password
  Retype password [4 to 32 half‑size characters]
<Initial setting: blank>
The password is input here.
Enter the setting using the Set button.
p
 If “On” has been selected as the “User auth.” setting, 
control will no longer be exercised from the AW-RP50 
remote camera controller. 
Use “Host auth.” (page 85) if the AW-RP50 is to be used.
  Access level
<Initial setting: 3. Live only>
Select one of the following settings as the user access 
level.
Enter the setting using the Set button.
1. Administrator
This access level allows the user to 
perform all the unit’s operations.
2. Camera control This access level allows only Live 
screen operations to be performed.
3. Live only
This access level enables only Live 
screen to be displayed.
The unit cannot be operated or set.
  User check
A pull-down menu can be opened here, and the registered 
users checked.
A registered user is indicated in the form of “Registered 
user name [Access level]”.
(Example: admin[1])
To delete a registered user, select the user to be deleted, 
and click the Delete button on the right.