Hotpoint SHS53X Benutzerhandbuch

Seite von 16
3
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
DATA PLATE 
Dimensions 
width cm 43.5 
height cm 32 
depth cm 41.5 
Volume 
lt. 58 
Electrical 
connections 
voltage: 230-240V ~ 50/60 Hz or 
50Hz  (see data plate) 
maximum power absorbed 
2250-2400W
 
ENERGY LABEL 
Directive 2002/40/EC on the label 
of electric ovens.  
Standard EN 50304 
Energy consumption for Natural 
convection – heating mode: 
a
 
Convection mode 
 
Declared energy consumption for 
Forced convection Class – heating 
mode: 
b
 Multi-cooking 
 
This appliance conforms to the 
following European Economic 
Community directives:  
- 2006/95/EEC of 12/12/06 (Low 
Voltage) and subsequent 
amendments; 
-2004/108/EEC of 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments; 
- 93/68/EEC of 22/07/93 and 
subsequent amendments. 
- 2002/96/EC and subsequent 
amendments. 
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance.  The power voltage and frequency
are as indicated on the rating plate.
!  THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
Fitting the power supply cable
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(
see diagram
).
2. Install the power
supply cable by
loosening the cable
clamp screw and the
three wire contact
screws L-N-
.
Connect the wires to
the corresponding
terminals: the Blue wire
to the terminal marked
(N), the Brown wire to
the terminal marked (L)
and the Yellow/Green
wire to the terminal
marked 
  (
see diagram
).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Electrical Connection:
Voltage Frequency: 230 V-1+N  50Hz
Fuse Section: 16A
Supply cable: 3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker
 - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal board.
N
L