McCall Refrigeration MCCSTR27 Benutzerhandbuch

Seite von 16
Compact Refrigerators and Freezers Service and Installation Manual
5
For customer service, call (888) 732-2446, Fax (800) 669-0619, www.mccallrefrigeration.com
After the unit is connected to power it will automatically begin 
operating.  With  the  doors  closed,  the  temperature  of  the 
cabinet should reach 36°F to 40°F (2°C to 4°C) on refrigerators 
or 0°F (-18°C) on freezers in about one hour. 
Temperature control instruction
Refrigerators: A thermostat located in the evaporator housing 
on interior rear of the unit, controls the temperature in the box. 
The factory setting for the control is “4” and maintains about 
38°F (3°C) in the box. Set toward “1” for higher temperatures 
and toward “7” for lower temperatures.
Freezers: A thermostat located in the evaporator housing on 
interior rear of the unit, controls the temperature in the box. 
The factory setting for the control is “4” and maintains about -
3°F (-18°C) in the box. Set toward “1” for higher temperatures 
and toward “7” for lower temperatures.
Continuous  opening  and  closing  of  the  doors  will  hamper  the 
unit’s ability to maintain optimum refrigeration temperature.
Illustration 1:
spacer outside
Illustration 2:
spacer inside
Adjusting door hinges
Doors  have  been  adjusted  at  the  factory.    If  it  becomes 
necessary to adjust a door, follow these instructions:
1)  If the door needs lowering at the handle, use a 5/16” wrench 
to loosen the hinge screws and install a spacer outside of 
the hinge (see illustration 1). Tighten the screws.
2)  If the door needs to be higher at the handle, use a 5/16” 
wrench  to  loosen  the  hinge  screws  and  install  a  spacer 
inside of the hinge (see illustration 2). Tighten the screws.
Refrigerators
Refrigerators  defrost  automatically  with  every  cycle  of  the 
compressor. The water generated is routed to a pan on the 
rear of the unit and is evaporated by the heat given off by the 
compressor.
Freezers
When defrost control goes into defrost, power to the condensing 
unit and evaporator fans is interrupted and the defrost heater 
is  energized.  The  defrost  heater  warms  the  evaporator  coil 
thereby  melting  all  frost  accumulated  during  the  previous 
refrigeration cycle. Once all frost is eliminated, the temperature 
of the coil continues to rise until it reaches 27 minutes. The 
defrost  control  switches  to  refrigeration  mode.    Defrost  will 
initiate every six hours.
Turn  the  screw  ONLY  in  a  clockwise  direction, 
turning  the  screw  counter-clockwise  will  break 
the cam motor.
Operation
Door Maintenance
Defrosting