Specification Sheet
 Page 
 
 
DVS205 Dual-Variable Sensor Specifications (continued) 
CONSTRUCTION 
Standard: Transducer is all stainless steel 
construction with silicone fill fluid, 316L 
diaphragms and glass-filled PTFE o-rings. 
Coupling is A360 Aluminum with urethane coating.
Optional: Transducer includes Hastelloy C-276 
wetted parts (construction is NACE compliant per 
MR0103 and ISO15156/MR0175), inert fill fluid. 
Coupling is available in 316 stainless steel 
(CF8M). 
MOUNTING  
Factory-installed on enclosure of FB103, FB107E, 
and FB503. See respective specification sheet for 
unit mounting options. 
CONNECTIONS 
Process: 1/4-18 NPT on 2-1/8 inch centers (on 
coplanar flange). 
APPROVALS  
Same as the FloBoss unit in which it is installed.