Southbend SB1017 Benutzerhandbuch

Seite von 56
TROUBLESHOOTING
-38-
For Machines Mfg. Since 8/09
Model SB1017
TROUBLESHOOTING
If you need replacement parts, or if you are unsure how to do any of the solutions given here, feel free 
to call us at (360) 734-1540.
Machine does not 
start.
1.
Power supply switched off/has 
incorrect voltage.
1.
Switch power supply on/verify voltage.
2.
Blown fuse/tripped circuit breaker 
at main panel.
2.
Correct the cause of overload, then reset/replace 
fuse or breaker.
3.
Plug or receptacle is corroded or 
mis-wired.
3.
Clean/retighten contacts; correct the wiring.
4.
Break or short in wiring; or loose 
connections.
4.
Trace/replace broken or corroded wires; fix loose 
connections.
5.
Motor connection wired incorrectly.
5.
Wire motor correctly (refer to inside junction box 
cover or manual). 
6.
Motor ON/OFF switch at fault. 
6.
Replace switch.
7.
Start capacitor blown or at fault.
7.
Replace start capacitor.
8.
Centrifugal switch at fault.
8.
Adjust/replace centrifugal switch.
9.
Motor at fault.
9.
Test for shorted windings, bad bearings and repair 
or replace.
Machine has 
excessive vibration 
or noise.
1.
Blade is missing teeth.
1.
Replace blade.
2.
Motor fan rubbing on fan cover.
2.
Fix/replace fan cover; replace loose or damaged fan.
3.
Motor or table is loose.
3.
Tighten any loose fasteners.
4.
V-belt loose.
4.
Tighten V-belt.
5.
Guide post lock lever is loose.
5.
Tighten the lock lever.
6.
Machine incorrectly mounted on 
floor.
6.
Level/shim base; tighten/adjust mounting hardware 
or feet.
7.
V-belt worn or damaged.
7.
Replace V-belt. Use a link belt if possible.
8.
Pulley loose or not in alignment; 
shaft bent.
8.
Replace worn pulley, key, and shaft, and realign.
9.
Centrifugal switch out of 
adjustment; at fault.
9.
Adjust/replace centrifugal switch.
10.
Motor bearings worn or damaged.
10.
Replace motor bearings or replace motor.
Motor chatters 
during startup or 
during operation.
1.
Extension cord (if used) is causing 
voltage drop.
1.
Move machine closer to the power source or use a 
larger gauge or shorter extension cord.
2.
Power supply has incorrect voltage 
on one or more legs.
2.
Contact your power company to fix the power 
supply.
Symptom
Possible Cause
Possible Solution
!