Ingersoll-Rand 4581740 Benutzerhandbuch

Seite von 48
04581740_ed2 
19
Figure 17 - Quick Setup Screen
To complete the parameters in the Quick Setup sub-menu: 
1.  Press the Setup menu button, then press Enter to choose the first sub-menu, Quick Setup.
2.  Use the arrow keys to move to one of the eight lines representing Configurations 1 through 8.
3.  Press Enter to bring up the Step 2, the first of two data entry screens used for setting up a Configuration. 
4.  Move to the Strategy parameter and select either Torque Control or Angle Control.
5.  Select a direction CW (Clockwise) or CCW (Counter-clockwise).
6.  Move to the next parameter on the screen and choose Torque Units: Nm, Ft-lbs, In-lbs, Kg-m, or dN.
7.  Choose the button with the right arrow and press Enter to move to the second page of the Configuration setup process.
8.  Using the numeric keypad, enter the desired target value for your fastening operation into the Torque Target or 
Angle Target data entry box, depending on which of the two strategies you selected for a particular Configuration.  
9.  The Insight software automatically assigns values within target limits to the other torque or angle control 
parameters displayed on this screen. If you want to edit any of these values, navigate to the data entry box and 
enter a new value using the numeric keypad. These parameters include:
Torque High Limit The maximum acceptable torque value for a fastening.
Torque Low Limit
The maximum acceptable torque value for a fastening.
Angle High Limit
The maximum acceptable angle through which the fastener may turn.
Angle Low Limit
The minimum angle through which the fastener must turn.
Torque Threshold The torque required to seat components in the joint; also the torque point 
at which angle begins to be measured.
Free Speed
The maximum % speed the spindle can turn during fastening.
Shiftdown Point
The point during the final stage of tightening at which the spindle shifts to 
a lower speed to improve accuracy.
Shiftdown Speed
The spindle % speed during the shiftdown phase.
10.  If the assembly requires that multiple bolts are fastened in sequence, enter a Gang Count in the applicable data 
entry box. See below for more information on Gang Count.
11.  If you wish to setup the Insight to move through a specific sequence of fastening Configurations, use the Auto 
Increment parameter. Enter the number of the Configuration you wish the Insight to use upon completion of the 
current Configuration. See below for more information on Auto Increment. 
12.  Enter an Increment Reset parameter to indicate which Configuration the Insight should use after a Configuration 
Reset Signal is received.
13.  After you have completed entering all the parameters for your Configuration, 
you must go to the Save button and hit Enter to store the settings you just 
entered. 
Save Button
Gang Count
Some assemblies have multiple bolts that must be fastened in sequence (called a “Gang”). For example, if you have a 
four-bolt assembly you can set the Gang Count to 4. The controller then keeps track of each fastening and, when all four 
fastenings have been completed within specification, a “Gang Complete” message appears on the display screen.