Ingersoll-Rand 4581740 Benutzerhandbuch
04581740_ed2
43
Appendix 2 – Event Codes
The following table lists the Event Codes for the IC-D and IC-M. Below is an explanation of table columns.
Event Code Explanation
Event Code
This is the event code number. On an IC-M controller, the code is displayed on the screen as “E” and then the code
number, for example, E002. For a IC-D controller, text detailing the error is placed in the systems dialog and warnings
box at the bottom of the Run Main screen.
Description/Condition
Description of Error.
Critical Error
If yes, then error condition must be resolved before system can run.
Action Required/Explanation
Action required to resolve error
Display on IC-D, IC- M GUI
Indicates which systems the error is displayed on. Some errors of secondary importance are only shown on the I320D
controller.
Event Code Table
Event
Code
Description/Condition
Critical
Error
Action Required/Explanation
Display
on D, M
GUI
Boot-up Events 001 to 060
002
002
Language File not found
Yes
Load language file to controller and re-boot
D,M
004
A system file has been lost (previously
existed)
No
None
D
005
Unable to initialize serial port
No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
006
Unable to initialize Ethernet port
No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
016
Restore Can2 switch
No
Restore the Can2 switches to “00”
D,M
027
Invalid Boot Image
Yes
Call authorized Ingersoll Rand service center
D,M
028,
029
Invalid Image
Yes
Load, Reload new application. If error still occurs
call authorized Ingersoll Rand service center
D,M
030
Error setting IP address
No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D,M
Tool Events 061 to 080
061
061
Tool has been disabled through I/O
No
None
D
063
Tool Stall detected
No
None
D, M
064
Tool Hall Fault
Yes
Check Tool and Tool cable
D, M
065
Tool IGBT Fault
Yes
Check Tool and Tool cable
D, M
066
Tool Over Current
No
Check tool size correct for application
D, M
067
Tool Low Bus Voltage
No
Ensure Source line voltage is not dropping under
load. If error still occurs call authorized Ingersoll
Rand service center
D, M
068
Tool Cycle Timeout
No
None
D
071
Tool Memory Write Fail
No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D, M
072
Tool Memory Read Fail
No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D
073
Tool Memory Page Set Fail
No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D
074
Tool Factory Null TR
No
Call authorized Ingersoll Rand service center
D, M