Maintenance 
6
312388K
Maintenance
Flushing
Flush before changing colors, before fluid can 
dry in the equipment, at the end of the day, 
before storing, and before repairing equip-
ment. Use a solvent that is compatible with gun 
wetted parts and fluid that will be sprayed.
Gravity Feed Guns:
1. Follow Pressure Relief Procedure
2. Dispose of any paint in the cup.
3. Fill the cup with a small amount of solvent.
4. Spray into a grounded metal waste 
container until clean solvent dispenses.
5. Follow Pressure Relief Procedure
Pressure Feed Guns:
1. Follow Pressure Relief Procedure
2. Disconnect fluid supply hose and air supply 
hose from gun.
3. Connect solvent supply hose to gun.
4. Hold metal part of gun against a grounded 
metal container, trigger, and flush the gun 
with solvent until all traces of paint are 
removed from the gun passages.
5. Turn off the solvent supply.
6. Follow Pressure Relief Procedure
7. Disconnect solvent supply hose from gun.
Daily Cleaning
2. Clean fluid and air line filters.
3. Check for fluid leakage from gun and 
fluid hoses. Tighten fittings or replace 
equipment as needed.
4. Flush gun before changing colors and 
when you are done spraying.
5. Remove cup and filter and clean them 
(gravity feed models only).
6. Remove air cap (1) and nozzle (2) as 
instructed on page 8 and soak them in 
compatible solvent.
7. Use a rag moistened in solvent to wipe 
down outside of gun.
8. Before reinstalling air cap and nozzle, clean 
them and front of gun with a soft-bristle 
brush dipped into compatible solvent. 
Do not use a wire brush or metal tools. 
To clean out air cap holes, use a soft 
implement, such as a toothpick.
9. Lubricate gun.
CAUTION
• Do not submerge gun in solvent. Solvent 
dissolves lubricant, dries out packings, and 
may clog air passages. You can immerse 
front end of gun in solvent just until cup 
connection is covered.
• Do not use metal tools to clean air cap 
holes as this may scratch them and distort 
the spray pattern.
• Use a compatible solvent.
CAUTION
Trigger gun and use gun tool (27) whenever 
you tighten or remove nozzle (2) to avoid 
damaging needle seat and nozzle.