Graco 247936 Benutzerhandbuch

Seite von 44
Gun Repair 
34
312900G
Repair Fluid Adjustment Valve 
1.
Prepare the gun for repair, page 27.
2.
Remove the fluid adjustment valve (25). It can only 
be replaced as a complete assembly. See F
3.
Screw the valve (25) into the gun handle. Torque to 
15-25 in-lb (1.7-2.8 N•m).
Fig. 20. Fluid Adjustment Valve
Repair Air Valve 
1.
Prepare the gun for service, page 27.
2.
Remove the barrel, page 31.
3.
Remove the fluid adjustment valve (25) from the 
handle (17). Remove the spring (15). See F
4.
Remove the air valve (21) with a pliers. Inspect the 
rubber sealing surface and replace the air valve if 
damaged.
5.
Inspect the u-cup (6*). Do not remove the u-cup 
unless damaged. If removed, install the new one 
with its lips facing into the gun handle (17).
6.
Install the air valve (21) and spring (15) into the gun 
handle (17). 
7.
Install the fluid adjustment valve (25). Torque to 
15-25 in-lb (1.7-2.8 N•m).
8.
Install the barrel, page 31.
Fig. 21. Air Valve
NOTICE
Clean all parts in non-conductive solvent compati-
ble with the fluid being used, such as xylol or min-
eral spirits. Use of conductive solvents can cause 
the gun to malfunction. 
NOTICE
When removing the air valve (21) be careful not to 
damage the seat area.The rubber seal is not 
removable. 
25
ti11931
25
15
21
*6
17
ti12717