Grounding
332758A
11
Grounding
Air and fluid hoses: use only electrically conductive 
hoses with a maximum of 500 ft. (150 m) combined 
hose length to ensure grounding continuity. Check elec-
trical resistance of hoses. If total resistance to ground 
exceeds 29 megohms, replace hose immediately.
Spray gun:
 
ground through connection to a properly 
grounded fluid hose and pump.
Fluid supply container: follow local code. 
Object being sprayed: follow local code. 
Solvent pails used when flushing: follow local code. 
Use only conductive metal pails, placed on a grounded 
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts 
grounding continuity.
To maintain grounding continuity when flushing or 
relieving pressure:
 hold metal part of the spray 
gun/dispense valve firmly to the side of a grounded 
metal pail, then trigger the gun/valve.
Power Requirements: 100-120V units require 
100-120 VAC, 50/60 Hz, 11A, 1 phase. 230V units 
require 230 VAC, 50/60 HZ, 7.5A, 1 phase.
The sprayer cord includes a grounding wire with an 
appropriate grounding contact.
The plug must be plugged into an outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances.
Do not modify the plug provided; if it does not fit the 
outlet, have the proper outlet installed by a qualified 
electrician.
Extension Cords: Use an extension cord with an 
undamaged ground contact. If an extension cord is nec-
essary, use a 3-wire, 12 AWG (2.5 mm
2
) minimum.
NOTE: Smaller gauge or longer extension cords may 
reduce sprayer performance. 
The equipment must be grounded to reduce the risk 
of static sparking and electric shock. Electric or static 
sparking can cause fumes to ignite or explode. 
Improper grounding can cause electric shock. 
Grounding provides an escape wire for the electric 
current.