Cleanup 
16
332758A
Cleanup
1.
Relieve Pressure, page 10.
2.
Remove guard and Spray Tip. For additional infor-
mation, see separate gun manual.
3.
Remove siphon tube set from paint. Wipe excess 
paint off outside of tubes. 
4.
Place siphon tube in flushing fluid. Use water for 
water base paint and mineral spirits for oil base 
paint. Place drain tube in waste pail.
5.
Turn prime valve horizontal.
6.
Hold gun against paint pail. Disengage trigger lock. 
Trigger gun and increase pressure until the pump 
runs steady and flushing fluid appears.
7.
Stop triggering gun. Move gun to waste pail, hold 
gun against pail, trigger gun to thoroughly flush sys-
tem. 
8.
While continuing to trigger gun, turn prime valve 
down. Then, release gun trigger. Allow flushing fluid 
to circulate until fluid coming out of drain tube is 
clear.
ti2769a
TIA
Flush
Waste
ti2756b
ti22221a
Paint
1/4 Turn
ti22223a
ti2599ab
ti22220a