Cleaning the Inlet Valve
Cleaning or servicing the inlet valve may be required if the unit has priming problems.  Priming problems may be 
prevented by properly cleaning the sprayer and following the long-term storage steps.
  1.  Remove the suction set.   
  3.  Lubricate the O-ring on the inlet valve (b).  Replace inlet 
valve assembly by screwing it into the sprayer.  Torque 
to 23-27 ft lbs (9145, 9155) or 32-38 ft lbs (9175. 9195).  
  2.  Unscrew the inlet valve assembly (a) from the sprayer.  
Visually inspect the inside and outside of the inlet valve 
assembly.  Clean any paint residue with the appropriate 
cleaning solution.  
  4.  Replace suction set and hand-tighten.
(a)
(b)
If priming problems persist, you may need to replace the 
inlet valve assembly.  Call Technical Service (1-800-880-
0993) to order new inlet valve assembly.