Device Settings 
Device List 
This page allows you to check the status of a known device and override the interface 
descriptions and speeds obtained from it. 
The name and address of each known device is listed, along with an icon indicating its 
status; an exclamation ( ) indicates that the device could not be contacted using 
SNMP or it is being ignored due to a license violation and an hourglass ( ) indicates 
that the device is currently being scanned and cannot be edited. You can update the 
list to see if a scan has finished by clicking “Refresh”. If no icon is displayed the device 
is working correctly. 
Clicking the name of the device you wish to edit will open a new page. It is important to 
remember that any changes you make to any device are only applied when you click 
“Ok” in the main device settings page. 
Device Settings 
The settings page for a single device allows you to set its SNMP properties, override 
the name and local AS number detected using SNMP and override the default “Show 
interface descriptions” 
value for the device. 
The local AS number is required to get correct AS numbers for traffic routed to or 
from the local AS in a BGP environment; if you do not use BGP this value should be left 
blank. 
A BGP device may be configurable to send the BGP next-hop address in its NetFlow 
exports; if this is the case you will have the option to store this value in place of the IP 
next-hop for the device. 
SNMP 
If the device does not support SNMP you can change the SNMP mode to “Don’t use 
SNMP”. This will assign default properties to each interface encountered in NetFlow 
exports from the device. It is also possible to freeze a device’s configuration by 
changing the mode to “Keep current configuration” – this will cause any new interface 
encountered to be ignored, so should be used with caution. If possible you should allow 
NetFlow Tracker to use SNMP to scan a device as the numbers used to identify the 
inbound and outbound interfaces in NetFlow exports are not constant and SNMP is the 
only way NetFlow Tracker can work out a correct correlation between an identifiers and 
physical interface or port. 
You can request an immediate rescan of an SNMP device by clicking “Rescan”. This will 
scan the device using the SNMP version and community specified in the page but will 
not save them; you must click “Ok” on the main device settings page before any 
changes are applied. Note that NetFlow Tracker rescans a device when it is restarted, 
if a new interface is encountered or if it appears the device was rebooted, so you will 
not normally have to manually rescan a device.