Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
•  The light control requires 120-volts AC. 
Do not con-
nect through a dimmer or other electronic switch.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
• 
Some  codes  require  installation  by  a  qualified 
electrician.
•  This product is intended for use with a junction box 
marked for use in wet locations.
•  The backplate has knockouts so the sensor can be 
mounted on most junction boxes.
•  In some applications a universal adaptor plate may 
be needed. Adaptors are available at home centers 
and electrical supply stores.
Cover 
Plate
Light Control
Sensor
3 Wire 
Connectors
Gasket
6 Mounting 
Screws (3 sizes)
This package includes:
Mounting Strap
Mounting Bolt
Rubber Plug
Plastic Hanger
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1 
TEST
ON-TIME
Put  the  ON-TIME  switch  on  the 
bottom of the sensor in the TEST 
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF 
then...
Note: When first turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
Manual  mode  only  works  at  night 
because  daylight  returns  the  sensor 
to AUTO.
Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.
Put the ON-TIME switch in the 1, 5, 
or 10 minute position.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x
Compact 150 Watt Motion
Sensing Halogen
Halogen