Lightolier FBP50 Merkblatt

Seite von 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
FBP Series Fluorescent Emergency Ballast
  FBP50
Page 1 of 1 
One or Two Lamp Operation 1,400 Lumens
Lightolier is a Philips group brand
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
13.3”
(33.9 cm)
2.4”
(6.1 cm)
1.5”
(3.8 cm)
Complete Fixture consists of ballast unit. Select options and accessories below.
Model # 
Max. Lumens 
Lamp Operation
FBP50 
1,400 
One or Two
 
Lamp Operation and Performance (continued)
   
 
 
Non-Emer.  Emer. Op. 
     
 
  
Max. 
Max. 
Emer. 
 Lamp 
 
Base 
 Lumen 
Lumen 
Lamp
 Type 
Watt.  
Type 
Output 
Output 
Operation
 F96T12HO 
       95 
 R17D/Recessed 
8000 
1100 - 1400 
One
F48T12 
110 
R17D/Recessed 
6200 
1100 - 1400 
One
 F17T8 
17 
G13/Med Bi-Pin 
1325 
1100 - 1400 
One or Two
 F25T8 
25 
G13/Med Bi-Pin 
2080 
1100 - 1400 
One or Two
 F32T8 
32 
G13/Med Bi-Pin 
2850 
1100 - 1400 
One or Two
 F32T8/U 
32 
G13/Med Bi-Pin 
2700 
1100 - 1400 
One or Two
 F40T8 
40 
G13/Med Bi-Pin 
3600 
1100 - 1400 
One
 F96T8 
59 
FA8/Single-Pin 
5800 
1100 - 1400 
One
F27BX 
27 
2G11/4--Pin 
1800 
1000 
Two
 F282D 
28 
GR10Q-4/4 Pin 
2050 
1100 
One or Two
 F382D 
38 
GR10Q-4/4 Pin 
2850 
1000 
One or Two
 F39/36BX 
39 
2G11/4--Pin 
2850 
1100 
One or Two
 F40/30BX 
40 
2G11/4--Pin 
3150 
1100 
One
 F50BX/FT55 
50-55 
2G11/4--Pin 
4300-4800 
1100 
One or Two
F96T12HO 
95 
R17D/Recessed 
8000 
1100 - 1400 
One
F96T12VHO 
95 
R17D/Recessed 
8000 
1100 - 1400 
One
Notes: 
1.  Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient 
operating temperature, and ballast manufacturer.
2.  Maximum emergency lumen output is based on total output of one or two lamps, and can 
vary based on lamp manufacturer and ambient operating temperature.
3.  Maximum emergency lumen output is supported for a full 90 minutes of operation.
4.  Consult factory for compatibility, operation and performance of lamp types not listed.
Features
1.  Lamp Operation: Operates the following lamp types: T8 linear fluorescent, 
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent, 
compact 4-pin fluorescent. See Lamp Operation and Performance table for 
specific lamp performance and operation
.
2.  Illumination: Provides 90 minutes of emergency illumination, and produces 
a maximum of 1,100 to 1,400 lumens initial emergency light output. Can be 
used with most 17w to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps with-
out integral starters including U-shaped, HO, VHO, circline, energy saving, 
and 4 pin compacts. It is also compatible with most 1, 2, 3 and 4-lamp elec-
tronic, standard, energy saving and dimming AC ballasts.
3.  Housing: Constructed of 20 gauge steel with a high temperature powder 
coat paint finish. Slim housing allows for wireway channel mounting on most 
recessed luminaires.
4.  Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test 
switch.
5.  Battery: Maintenance free, sealed nickel cadmium battery has an estimated 
service life of 10 years, and an operating temperature range of 32°F (0°C) to 
131°F (55°C). 
 
6.  Input Power Requirements: 4 watts max.
7.  Warranty: Electronics: 5 years; Battery: 5 years.
Code Compliance
UL 924 listed, damp location listing optional. 
UL listed for use within sealed and/or gasketed luminaires.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. 
Contact factory for other input voltages and frequencies. 
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote 
installation of test switch and pilot light.
Lamp Operation and Performance
   
 
 
Non-Emer.  Emer. Op. 
     
 
  
Max. 
Max. 
Emer.
 Lamp 
 
Base 
 Lumen 
Lumen 
Lamp
 Type 
Watt.  
Type 
Output 
Output 
Operation
F20T12 
20 
G13/Med Bi-Pin 
1275 
1100 - 1400 
One or Two
 F30T12 
30 
G13/Med Bi-Pin 
2350 
1100 - 1400 
One or Two
 F40T12 
40 
G13/Med Bi-Pin 
2650 
1100 - 1400 
One or Two
F40T12/U 
40 
G13/Med Bi-Pin 
3100 
1100 - 1400 
One or Two 
F48T12 
40 
FA8/Single-Pin 
2875 
1100 - 1400 
One or Two
 F60T12 
50 
FA8/Single-Pin 
3600 
1100 - 1400 
One
 F72T12 
55 
FA8/Single-Pin 
4500 
1100 - 1400 
One
F96T12 
75 
FA8/Single-Pin 
5500 
1100 - 1400 
One
 F24T12HO 
35 
R17D/Recessed 
1620 
1100 - 1400 
One
 F36T12HO 
45 
R17D/Recessed 
2800 
1100 - 1400 
One
 F48T12HO 
60 
R17D/Recessed 
5150 
1100 - 1400 
One
 F60T12HO 
75 
R17D/Recessed 
4050 
1100 - 1400 
One
F72T12HO 
85 
R17D/Recessed 
6350 
1100 - 1400 
One
Nickel Cadmium Battery