Model T10687 (Mfg. Since 10/12)
-13-
Extension Cords
This  tool  is  double-insulated  and  therefore  does 
not  have  a  grounding  wire  or  plug.  The  two-
pronged,  NEMA  1-15  plug  has  a  polarized  end; 
this  means  that  one  prong  (the  neutral  connec-
tor)  is  wider  than  the  other  (the  hot  connector). 
Polarized plugs must be used only with polarized 
receptacles. Do not attempt to plug this tool into a 
non-polarized receptacle. If a polarized receptacle 
is  not  available,  a  qualified  electrical  technician 
will  have  to  install  one  before  the  saw  can  be 
plugged in.
Polarized Plug
Figure 3. Typical 1-15 plug and receptacle.
5-15 Receptacle
1-15 Plug
Neutral
Hot
When using extension cords, make sure the cords 
are rated for outdoor use. Outdoor use cords are 
marked with a "W-A" or a "W" to signify their rat-
ing. Always check to make sure that the extension 
cords are in good working order and free of any 
type  of  damage,  such  as  exposed  wires,  cuts, 
creased bends, or missing prongs.
Extension  cords  cause  voltage  drop,  which  may 
damage electrical components and shorten motor 
life. Voltage drop increases as the extension cord 
size gets longer and the gauge size gets smaller 
(higher  gauge  numbers  indicate  smaller  sizes. 
When using extension cords, always choose the 
shortest  cord  possible,  with  the  greatest-sized 
gauge.  
Below is a list of minimum gauge sizes needed for 
running this tool at different lengths:
25 Feet ....................................................16AWG
50 Feet ....................................................14AWG
100 Feet ..................................................12AWG
Over 100 Feet .................... Not Recommended