Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires power. 
 
©2004 Maytag Services 
16023416 
17 
 
Illustration/Component Test 
Procedure 
Results 
Control Panel Assembly 
 
 
Model MER6875A** 
Continuity is indicated as follows: 
1000 – 6600 
Ω for Cancel and 
Warming Zone pads 
1000 – 10000 
Ω for All other pads 
 
1
18
11
10
 
 
Pad 










Lower Cancel 
Upper Cancel 
Convect Bake 
Delay 
Clock 
Favorite 
Lower Clean 
Upper Clean 
Lower Bake 
Lower Light 
Upper Keep Warm 
Upper Light 
Autoset 
Lower Keep Warm 
Conv Roast 
Lower Broil 
Upper Bake 
Timer 2 
Cook & Hold 
Upper Broil 
Timer 1 
Toast 
Warm Zone 
Trace 
14 & 16 
16 & 17 
6 & 8 
6 & 7 
8 & 17 
7 & 14 
6 & 15 
5 & 14 
6 & 14 
8 & 14 
1 & 2 or 3 
11 & 12 or 13
4 & 15 
6 & 16 
5 & 16 
5 & 7 
5 & 15 
7 & 16 
8 & 15 
7 & 15 
7 & 17 
15 & 16 
14 & 17 
8 & 16 
4 & 8 
4 & 5 
4 & 14 
4 & 7 
5 & 6 
14 & 15 
4 & 16 
7 & 8 
4 & 6 or 17 
Measurement
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
 
 
 
Models MER6555A**, MER6751AA*, MER6755A**, MER6775A** Membrane and Overlay