Technical data
Dimensions
width 60 cm
height 85 cm
depth 60 cm
Capacity
14 standard place-settings
Water supply 
pressure
0,05 ÷ 1MPa (0.5 ÷ 10 bar)
7,25 – 145 psi
Power supply voltage See appliance data plate
Total absorbed power See appliance data plate
Fuse
See appliance data plate
This dishwasher conforms to the 
following European Community 
Directives: 
-2006/95/EC  (Low Voltage)
-2004/108/EC (Electromagnetic 
Compatibility) 
-2009/125/EC (Comm. Reg. 
1016/2010) (Ecodesign)
-97/17/EC (Labelling)
-2012/19/EU Waste Electrical 
and Electronic Equipment 
(WEEE)
The  Company  shall  not  be  held  responsible  for  any
incidents that occur if these regulations are not observed.
Anti-condensation strip
*
After installing the dishwasher, open the door and stick the 
adhesive transparent strip under the wooden shelf in order to 
protect it from any condensation which may form.
Connecting the water supplies
Connection to the water and electricity supplies should
only be performed by a qualified technician.
The dishwasher should not stand on top of the water 
hoses or the electricity supply cable.
Connecting the water inlet hose
The water inlet and outlet hoses and the electricity supply 
cable may be positioned towards the right or the left in order 
to achieve the best possible installation.
•  To a suitable cold water connection point: before attaching
the hose, run the water until it is perfectly clear so that any 
impurities that may be present in the water do not clog the 
appliance; after performing this operation, screw the inlet 
hose tightly onto a tap with a ¾ gas threaded connection.
•  To a suitable hot water connection point: your dishwasher
may be provided with hot water from the mains supply (if 
you have a central heating system with radiators) provided 
that it does not exceed a temperature of 60°C.
  Screw the hose to the tap as described for connection to 
a cold water supply.
If the inlet hose is not long enough, contact a specialist 
store or an authorised technician 
(see Assistance)
.
The water pressure must be within the values indicated 
in the Technical data table 
(see Installation).
The hose should not be bent or compressed. 
The appliance must be connected to the water supply 
network using new hoses.
Do not use old hoses.
Ensure that the new hose supplied is connected and the old 
hose is disposed of safely.
DO NOT overtighten the hose connector, hand tight is
sufficient.
Ensure the fill hose is not kinked.
Tap connections*: A range of adaptors are available to 
suit your tap.
DO  NOT  connect  the  dishwasher  to  a  single  outlet
instantaneous water heater or an electric heater.
Sink Waste System
Connect the outlet hose (without bending it) to a drain duct
with a minimum diameter of 32 mm.
The outlet hose must be at a height ranging from 40 to 80 cm
(from 15’’ to 31’’) from the floor/surface where the dishwasher
rests (A).
•  before  connecting  the  drain  hose,  remove  any  internal
restrictions; this will prevent a build up of debris which 
could cause a blockage
•  remove any restrictions from the waste spigot and ensure
that the sealing bung is removed (B).
It MUST NOT be connected to a surface water drain.
• Untie the end of the GREY drainage hose from the rear of
the appliance.
*
 
Only available in selected models.