3M MT7 Benutzerhandbuch

Seite von 59
3M™ MicroTouch™ Software MT 7 User Guide   
17 
3M Touch Systems, Inc. Proprietary Information – 25695M 
Controller Type 
This field displays the type of controller currently attached to your system. This data may 
be useful for Technical Support issues. The touch controllers supported with this release 
are as follows: 
 
EX USB, HID, and Serial capacitive and resistive controllers  
 
DX Dual mode (USB and Serial) controllers 
 
PX Dual mode (USB and Serial) controllers 
 
RX USB and Serial resistive controllers 
 
SX Serial pen controllers 
Firmware Version 
These digits represent the version number and revision level of the touch controller 
firmware. 
Sensor Status 
Sensor Status refers to whether or not the sensor has been found and is operational. 
Some of the possible messages include: 
 
OK – Sensor found and operational. 
 
BLK Error – Hardware error such as a checksum error in controller EEPROM. 
 
CBL Error – Cable NOVRAM missing – this is only an error in systems requiring 
cable NOVRAM. 
 
HDW Error – Hardware error.  
 
LIN Error – Linearity data error. 
 
NOV Error – Checksum error in NOVRAM, using defaults. 
 
PWM Error – Hardware error.  
 
ROM Error – Checksum error in ROM. 
 
SET Error – Unable to establish operating range at power-up.   
Any other condition indicates a hardware failure. Contact Technical Support for more 
information.