3.
 
The TWDrvStartup script must complete before running the X server. The 
TWDrvStartup script modifies the X server configuration file (either 
xorg.cfg
 or 
xfree86.cfg
). When the system shuts down, these files are restored to their 
original state. It also starts the touch driver, TwDriver. Scripts that launch the X 
server reference the programs xdm, gdm, or kdm. Symptoms of this are a lack of 
touch or possibly erratic touch with USB touch controllers. 
In each case, you need to rearrange the order of the init scripts to satisfy the requirements 
of the MT 7 for Linux® software. The method to do this is specific to your system's 
distribution. 
Troubleshooting Touch Behavior 
Many issues can affect touch. 
If you have no touch, it is likely that the X Windows server is starting before the MT 7 
for Linux® driver. First, inspect the X Windows configuration file, usually either 
/etc/X11/xorg.conf
 or 
/etc/X11/xfree86.conf
, and see if there is an entry 
for the "twxinput" driver. If this entry is present, inspect the X Windows server log file, 
usually either 
/var/log/Xorg.0.log 
or 
/var/log/XFree86.0.log
, to see if 
the driver loaded without error. If the entry is missing or there is an error in the log file, 
refer to the section above, "Troubleshooting the Init Script". 
If the cursor reacts to a touch but does not appear under your finger, usually a simple 
calibration fixes the problem. If it does not, open a terminal window and type the 
command 
"X -version". 
If the first line of the output starts with 
X.Org X 
Server 1.4
 then you may need to enable the "ConvertAtRead" option. Review the 
section on "Other Options" under "Installation" for details. 
Running Touch Applications 
There are two touch applications that you can run to customize the touch system. These 
programs reside in the directory where you installed the package. 
1.
 
The Calibration program aligns the sensor to the display's screen. You should run 
this program after installation or whenever adding a new sensor to the system. Run 
the program by running the TwCalib program. 
2.
 
The Control Panel provides more features to customize your touch system. Run this 
program as needed by running the StartCP script. 
Note:
 This is a Java® program and runs with the JRE from Oracle®. If you experience 
problems running the Control Panel, download a JRE from 
www.oracle.com
 and install 
it.  