Smeg CIR575X Benutzerhandbuch

Seite von 20
 
Instructions for the installer
 
 
 
14
 
5.3 Adjustment for natural gas 
The hob has been adjusted for natural gas at a pressure of 1.0kPa.  
To allow the unit to work back with this type of gas, after it has been 
adjusted for LPG, perform the same operations described in paragraph 
“5.2  Adjustment for LPG”, but refer to the following table for the proper 
injectors. 
 
 
NG – 1.0 kPa 
 
 
 
Burner (*) 
Nominal gas 
consumption 
(MJ/h) 
Injector 
(mm) 
Auxiliary (1) 
4.8 
0.98 
Semi rapid (2) 
6.0 
1.10 
Rapid (6) 
11.5 
1.50 
Rapid (3) 
12.2 
1.55 
Wok (4) 
15.0 
1.70 
Wok (dual control) (5) 
 
15.0 
 
Outer 
11.5 
1.50 
 
Inner 
3.5 
0.85 
 
(*) For burner reference numbers, see page 15.
 
 
 
 
 
6.  FINAL OPERATIONS 
Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “5.1  Removing the 
hob
”. 
 
6.1 Adjustment of minimum for natural gas 
Light the burner and take it to the minimum 
Remove the gas tap knob and turn the 
adjustment screw inside or at the side of the tap 
shaft (depending on the model) until there is a 
regular minimum flame. Replace the knob and 
check burner flame stability: (rapidly turning the 
knob from maximum to minimum position, the 
flame should not go out). Repeat the operation on 
all the gas taps.