Keating Of Chicago 1-800 Benutzerhandbuch

Seite von 12
A. PREPARING THE FILTER-DRAWER
CAUTION
WATER IN ANY FORM & HOT OIL DON'T MIX!
NOTE:  Operator should be outfitted with proper 
protective attire: safety goggles, oil and heat 
resistant gloves, apron and footwear
Filter assembly inside of cabinet:
1. Pull the handle marked “Pull to Release Filter” 
(top of filter panel).
2. Remove the entire assembly from the cabinet by rolling it 
forward.
3. Pull the handle marked “Pull to Release Tub” 
(bottom of panel) 
4. Slide the tub back, lift up and remove from cart.
5. Ensure all components are clean 
(NOTE: Filter tub and components are dishwasher safe).
6. Install components into tub as follows:
a. Sump screen
b. Filter paper
c. Hold down ring (Note 1)
d. Acidox (1 package per 40lbs oil) (Note 2)
e. Crumb basket
See Figure 1
NOTE 1: Hold down ring makes a gasket-like seal on filter
paper. Filter paper must be placed edge to edge from front to
back, overlapping on sides. Filter Paper must be smooth and
flat under hold down ring to get a proper seal. Lock the two
tension arms into place by pushing down and rotating 90°.
NOTE 2: One package of Acidox is needed for every 40
pounds of oil.
7. Place entire tub assembly onto the cart (NOTE: Ensure 
the lip on the tub goes under the cart frame in the rear).
8. Reconnect the tub to the motor by pulling together the 
handles on the front of the tub and the handles on the 
side of the motor housing.
See Figure 2
NOTE:  Push on the front of the tub to verify connection. If tub
moves, repeat steps 7-8.
SAFE & EASY
®
FILTER
OPERATING INSTRUCTIONS
KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL
– 1 –
CRUMB
BASKET
FILTER 
TUB
HOLD 
DOWN RING
FILTER
PAPER
SUMP
SCREEN
SPRINKLE ACIDOX EVENLY ON PAPER
FIGURE 1.  
FIGURE 2.  
Pull handles
to connect
tub to
pump
Motor Housing