Dimensions and Installation Information (in inches)
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
PP912TM/KM/BM 
GE Profile
™ 
30" Built-In CleanDesign Electric Cooktop
 
220581
Listed by 
Underwriters 
Laboratories
Note: Check local codes for required breaker size
Important: Requires a 5" free area between the 
bottom of the cooktop to any combustible material, 
i.e., shelving. Free area not required when installing 
wall oven underneath cooktop. Refer to installation 
instructions. Requires a 15" minimum from cooktop to 
adjacent overhead cabinets. Units are furnished with a 
48" flexible armored cable. 
Note: 30" Ribbon cooktops are approved for use over select GE 27" and GE 30" 
Single Wall Ovens and Warming Drawers. Refer to cooktop and wall oven/ 
warming drawer installation instructions packed with product for current  
dimensional data. If installed with a GE Profile
™ 
Telescopic Downdraft System, 
consult both the cooktop and downdraft installation instructions packed with 
product before installing. Cooktop gas/electric supply may need to be re-routed 
to install downdraft. Consult cabinet and countertop manufacturer’s specs for 
flush mount installation prior to install. 
Before installing, consult installation 
instructions packed with product for current dimensional data. 
Filler Trim Kit: When replacing an old GE 30" cooktop (with larger opening)  
use the following one-piece trim kit to fill in the over-size hole. Available at  
additional cost. JXTR32W (True White) JXTR32B (Black glass) JXTR32C (True 
Bisque)
KW Rating
240V
7.6
208V 5.7
Breaker Size
240V
40 Amps
208V 30 Amps
3-1/4*
Cooktop
2-1/2**
Required
28-1/2
19-5/8
29-3/4
30_color_cktp_install.eps
21-3/8
Electrical junction box 16" MIN. 
below countertop
30" MIN. to
unprotected
cabinet
Cut should 
not interfere 
with cabinet
structure 
at front
1-1/2" MIN.
clearance to
side wall
from cut-out
1-1/2" MIN.
clearance to
side wall
from cut-out
1-3/4" to
rear wall
13" MAX.
depth
  * Depth of unit at conduit connection location (rear) is 
6-1/2" on models PP980/975/950/945 and 4-5/8" 
on models PHP900/PP972/962/942/932/912, 
JP655/356/346.
 **Raised bull nose countertops may require up to 
3/8" additional clearance to prevent interference 
with curved front.
15" MIN.  
to cabinet