Ducted version air exhaust system Connection 
When installing the ducted version, connect the hood to 
the  chimney  using  either  a  flexible  or  rigid pipe ø 150 
or 120 mm, the choice of which is left to the installer. 
•  To install a ø 120 mm air exhaust connection, insert 
the reducer flange 9 on the hood body outlet. 
•  Fix the pipe using the pipe clamps 25 provided.  
•  Remove any activated charcoal filters. 
 
 
9
ø 120
ø 150
Recirculation version air outlet connection 
•  Insert reducer flange 9 on the extractor outlet. 
•  Push fit the extension piece 14 onto the flange. 
•  Push fit connector 15  onto the extension piece. 
•  Insert extension piece 14.2 laterally on connector 15, 
ensuring that the outlet is in line with the chimney in-
take. 
 
15
14
9
14.2