Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to the 
wall or floor with the two #12 x 1
⁵⁄₈" screws provided.
Install Downdraft System
Determine Equivalent Length of Vent System 
This range is equipped with a dual range blower. It is shipped 
from the factory for Low Range installations. If vent system 
equivalent length exceeds 30 ft (9.1 m), the downdraft blower 
motor must be converted to High Range for best performance. 
See “Calculating Vent System Length.”
To Convert:
Gently remove the spring loaded Restricter Ring from the blower 
inlet by pressing one of the 3 springs.
Determine which venting method to use: floor, rear wall, or left or 
right side venting. Go to the section for your type of venting.
Rear Wall Venting
1. Mark the wall at the center of the cabinet opening.
2. Check for obstructions before marking the vent hole location. 
Mark a horizontal line 8
³⁄₁₆" (20.8 cm) from the floor. Mark a 
vertical line up to a maximum of 2¼" (7.9 cm) from the right-
hand side of the cabinet centerline.
3. Draw and cut a 6¼" (15.8 cm) diameter hole.
4. Position blower motor in cabinet opening. Connect vent 
system to blower motor outlet using a vent clamp.
A. #12 x 1
⁵⁄₈" screws
B. Anti-tip bracket
A. Restricter ring
B. Spring
A
B
A
B
A. Maximum 2¼" (7.9 cm) from 
the right of center
B. 8
³⁄₁₆
" (20.8 cm) from floor
A. 6¼" (15.8 cm)
Top View
A. 18¾" (47.6 cm) maximum from back 
wall forward into cabinet opening
B. Inlet
C. Vent system
D. Vent clamp
E. Wall vent
B
A
A
A
B
C
D
E