Jenn-Air W10298937A Benutzerhandbuch

Seite von 24
10
Install Cooktop
1. Using 2 or more people, place cooktop right side up into the 
cutout.
NOTE: Make sure that the front edge of the cooktop is parallel 
to the front edge of the countertop. If repositioning is needed, 
lift entire cooktop up from the cutout to avoid scratching the 
countertop.
2. Connect blower exhaust scroll to ducting.
3. Use vent clamps to secure the ducting to the blower exhaust 
scroll.
4. Turn tie down bolts clockwise until they contact the bottom 
side of the countertop, then tighten 
¹⁄₄ turn more.
5. Install grease container(s) to bottom of cooktop.
6. Reinstall grease filter.
7. Reinstall vent grille.
Make Electrical Connection
This cooktop is manufactured with a white (neutral) power supply 
wire twisted together with a green (or bare) grounding wire 
connected to the cooktop.
Home power supply cable and connectors are not provided.
See the “Electrical Connection Options” chart to complete 
installation for your type of electrical connection.
Electrical Connection Options
4-Wire Cable from Home Power Supply to 4-Wire Cable 
to Cooktop 
IMPORTANT: Use the 4-wire cable from home power supply in 
the U.S. where local codes do not allow grounding through 
neutral, New Branch circuit installations (1996 NEC), mobile 
homes and recreational vehicles, new construction, and in 
Canada.
1. Disconnect power.
2. Remove wiring box cover from the cooktop plenum.
3. Remove the appropriate knockout for the size of the home 
power supply cable on the bottom side of the cooktop wiring 
box. Use a UL listed or CSA approved strain relief to connect 
home power supply cable to cooktop wiring box.
4. Connect the green (or bare) ground wire from the home power 
supply to the green (or bare) ground wire in the plenum wiring 
box using the UL listed wire connectors.
5. Connect the 2 black wires together using the UL listed wire 
connectors.
6. Connect the 2 red wires together using the UL listed wire 
connectors.
7. Connect the 2 white wires together the UL listed wire 
connectors.
8. Tighten screws on the strain relief.
9. Install cooktop wiring box cover on plenum wiring box.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire
A fused 
disconnect or 
circuit breaker 
box
4-Wire Cable from 
Power Supply 
3-wire
A fused 
disconnect or 
circuit breaker 
box
3-Wire Cable from 
Power Supply 
A. Green (or bare) ground wires
B. White wires
C. Black wires
D. Cable from home power supply
E. Plenum wiring box
F. Red wires
G. UL listed wire connector
H. UL listed or CSA approved 
strain relief
½"
(1.3 cm)
½"
(1.3 cm)
A
B
C
F
D
E
G
H