NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
Where possible, a 6" (15.2 cm) clearance is recommended for 
motor blower service. A minimum clearance of 1" (2.5 cm) is 
recommended to the sidewalls and a 
³⁄₄" (1.9 cm) clearance is 
recommended to the rear wall.
A minimum clearance of 
2" (5.1 cm) is recommended between 
the motor/blower and cabinet for proper cooling.
A minimum clearance of 
6¹⁄₄" (15.9 cm) is recommended for 
removal of the grease container(s). Installed dimension for the 
grease containers is 5
¹⁄₂" (14.0 cm). 
For grills installed near a sidewall, a minimum clearance of 
6" (15.2 cm) is recommended between the cooktop and 
sidewall for maximum performance.
Cutout Dimensions
Venting Requirements
Do not terminate the vent system in an attic or other enclosed 
area.
Use a Jenn-Air
®
 vent cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is 
recommended. For best performance, do not use plastic or 
metal foil vent.
Before making cutouts, make sure there is proper clearance 
within the wall or floor for the exhaust vent.
Do not cut a joist or stud unless absolutely necessary. If a joist 
or stud must be cut, then a supporting frame must be 
constructed.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.
Use only a 6" (15.2 cm) round metal vent or a 3
¹⁄₄" x 10" 
(8.3 x 25.4 cm) rectangular metal vent except for as follows:
For electric models, 5" (12.7 cm) diameter round metal 
vent may be used for venting straight out the back of the 
cooktop and directly through the wall for a duct length of 
10 ft (3.0 m) feet or less
For gas models, 5" (12.7 cm) diameter round metal vent 
must be used if the duct length is 10 ft (3.0 m) feet or less.
Do not use 5" (12.7 cm) elbows except in a 5" (12.7 cm) 
system. Instead, use a 5" (12.7 cm) to 6" (15.2 cm) elbow or a 
5" (12.7 cm) to 3
¹⁄₄" x 10" (8.3 x 25.4 cm) elbow transition.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the 
cap.
Determine which venting method is best for your application.
For Best Performance:
Use 26-gauge minimum galvanized or 25-gauge minimum 
aluminum metal vent. Poor quality pipe fittings can reduce 
airflow. Flexible metal vent is not recommended.
NOTE: Local codes may require a heavier gauge material.
Metal duct may be reduced to 30-gauge galvanized steel or 
26-gauge aluminized steel if allowed by local codes. This 
reduction is based on information in the International 
Residential Codes Section M1601.1 (2006 edition).
Do not install 2 elbows together.
Use no more than three 90° elbows.
If an elbow is used, install it as far away as possible from the 
hood’s vent motor exhaust opening.
A. 29" ± 
¹⁄₁₆" (73.6 cm ± 0.2 cm) on 30" (76.2 cm) models
43
¹⁄₄± ¹⁄₁₆" (109.9 cm ± 0.2 cm) on 45" (114.3 cm) models
B. 21" ± 
¹⁄₁₆" (53.3 cm ± 0.2 cm) maximum on both 30" (76.2 cm) and 
45" (114.3 cm) models
C. 9
³⁄₈" (23.8 cm)  on both 30" (76.2 cm) models and 45" (114.3 cm) 
models
D. 7
⁹⁄₁₆" (19.2 cm) on both 30" (76.2 cm) and 45" (114.3 cm) models
E. 1
⁷⁄₈" (4.8 cm) minimum space to front edge of cooktop
F. Floor exhaust option
G. 6
¹⁄₈" (15.6 cm) for 6" vent system
H. 9
³⁄₈" (21.9 cm) on both 30" (76.2 cm) and 45" (114.3 cm) models
I. 13" (33.0 cm) on both 30" (76.2 cm) and 45" (114.3 cm) models
J. Wall exhaust option
A
B
C
D
E
F
G
H
I
J