Jenn-Air 8112P341-60 Benutzerhandbuch

Seite von 36
S
URFACE
 
BURNER
 
FAILS
 
TO
 
LIGHT
.
• Check to be sure plug is securely inserted
into receptacle.
• Check or re-set circuit breaker.  Check
or replace fuse.
• Check power supply.
• Check to be sure burner is correctly
rated for your kind of gas.
• Check to be sure burner ports or ignition
ports are not clogged.
• Check to be sure ignitor is dry and
clicking. Burner will not light if ignitor is
damaged, soiled or wet. If ignitor doesn’t
click, turn control knob OFF.
• Check to be sure burner cap is correctly
seated on the burner base.
B
EFORE
 Y
OU
 C
ALL
 
FOR
 S
ERVICE
9
S
URFACE
 
BURNER
 
FLAME
 
LIFTS
OFF
 
PORTS
.
• Check to be sure a pan is sitting on the
grate above.
• Contact an authorized servicer.
T
HE
 
FLAME
 
IS
 
UNEVEN
.
• Burner ports may be clogged.
• Flame may need to be adjusted. Contact
an authorized servicer.
S
URFACE
 
BURNER
 
FLAME
 
IS
YELLOW
 
IN
 
COLOR
.
• Contact an authorized servicer.
• Some yellow tips on the flame are
acceptable when using LP gas.
G
LASS
-
CERAMIC
SURFACE
 
SHOWS
 
WEAR
.
1.Metal marks.
• Do not slide metal pans across top.
When cool, clean with Cooktop
Cleaning Creme. See pg. 8.
2.Brown streaks and specks.
• Spills were not removed promptly.
Surface was wiped with soiled cloth
or sponge.
3.Areas with a metallic sheen.
• Mineral deposits from water and food.
4.Pitting or flaking.
• Sugary boilovers that were not
removed promptly. See pg. 8.
I
GNITER
 
CONTINUES
 
TO
 
CLICK
.
• Be sure ignitors are dry.
9/8/06, 1:31 PM
10