Installation
Prior to installation, ensure that the local distribution 
conditions (nature of the gas and gas pressure) 
and the adjustment conditions are compatible. The 
adjustment conditions for this appliance are stated on 
the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a 
combustion products evacuation device. It must be 
installed and connected in accordance with current 
installation regulations. particular attention should 
be given to the relevant requirements regarding 
ventilation.
MODEL NUMBERS 
HUG61P,HUG61K,HUG61G,HUG61X,HAG 
60S,HAG60K,HAG60X,62DGW,62DGG,60
HGP, DSG60S,HAG60G,HAG60P
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20) 
at 20 mbar but can be converted for use on BUTANE 
(G30) at 28-30mbar with the use of the LPG conversion 
kit that can be obtained free of charge, if you contact 
our Genuine Parts and Accessories department (see 
Key Contacts, back page).
GAS SAFETY (INSTALLATION & USE) 
REGULATIONS
It is the law that all gas appliances are installed by 
competent persons in accordance with the current 
edition of the above regulations. It is in your interest 
and that of safety to ensure compliance with the 
law. In the UK, CORGI registered installers work to 
safe standards of practice. The cooker must also be 
installed in accordance with BS 6172. Failure to install 
the cooker correctly could invalidate the warranty 
liability claims and could lead to prosecution.
Adapting to different types of gas 
(main and top oven)
In order to adapt the oven to a different type of gas 
with respect to the gas for which it was manufactured 
(indicated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
  open the oven door fully
  pull out the sliding oven bottom
  Pry the fixing tab "V" and remove the oven burner
  Unscrew the oven burner nozzle using the socket 
spanner for the nozzles "Z", or a 7 mm socket 
spanner, and replace it with a nozzle suited to the 
new type of gas (see Table). Take particular care 
handling the spark plug wires and the thermocou-
ple pipes.
  Replace all the parts, following the steps described 
above in the reverse order.
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
Burner
Heat Input
Injector
Heat Input
Injector
Hotplate
Front Left and Rear Right
3.0 kW
116
3.0 kW (220g/h)
86
Hotplate
Front Right and Rear Left
2.0 kW
103
2.0 kW (145g/h)
70
Grill
3.7 kW
150 (X)
3.4 kW (246g/h)
91
Main Oven
2.5 kW
115
2.3 kW (166g/h)
71
Top Oven
1.9 kW
100
1.9 kW (136g/h)
66
V
V
Z
unscrew the two screws and take off the shield 
protecting the burner (in main oven burner only).
•