Hotpoint GX751RTX Benutzerhandbuch

Seite von 16
GB
7
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Replacing the nozzles on separate “double flame “ burners
1.  Remove the grids and slide the burners from their housings. The burner 
consists of 2 separate parts (see figure);
2.  Unscrew the burers with a 7 mm wrench spanner. The internal burner 
has a nozzle, the external burner has two (of the same size). Replace 
the nozzle with models suited to the new type of gas (see table 1).
3.  Replace all the components by repeating the steps in reverse order.
 
replacing the triple ring burner nozzles
1.  Remove the pan supports and lift the burners out of their housing. The 
burner consists of two separate parts (see pictures).
2.  Unscrew the nozzles using a 7 mm socket spanner. Replace the nozzles 
with models that are configured for use with the new type of gas (see Table 
1). The two nozzles have the same hole diameter.
3.  Replace all the components by completing the above operations in reverse 
order.
•  Adjusting the burners’ primary air
Does not require adjusting.
•  Setting the burners to minimum
1.  Turn the tap to the low flame position;
2.  Remove the knob and adjust the adjustment screw, which is positioned 
in or next to the tap pin, until the flame is small but steady.
! In the event of single-control DRDA (DCDR) burners, adjustment can be 
performed by intervening on the 2 screws located near the tap pin (see picture).
 
Inner DRDA (DCDR)
burner adjustment
Total DRDA 
(DCDR) burner
adjustment
3.  Having adjusted the flame to the required low setting, while the burner is 
alight, quickly change the position of the knob from minimum to maximum 
and vice versa several times, checking that the flame does not go out.
4.  Some appliances have a safety device (thermocouple) fitted. If the device 
fails to work when the burners are set to the low flame setting, increase 
this low flame setting using the adjusting screw.
5.  Once the adjustment has been made, replace the seals on the by-passes 
using sealing wax or a similar substance.
6.  In the event of discrete-adjustment knobs with LED visualisation, turn the 
knob to the minimum power setting them remove it and intervene on the 
adjustment screw located near the tap pin.
7.  Minimum setting adjustment of the DRDA (DCDR) burner with discrete 
adjustment and LED visualisation:
•  To adjust the outer ring, turn the knob anti-clockwise to the minimum 
power position.
•  To adjust the minimum power setting of the inner ring, turn the knob 
clockwise to the minimum power position.
•  Remove the knob and intervene on the adjustment screw located near 
the tap pin.
! If the appliance is connected to liquid gas, the regulation screw must be 
fastened as tightly as possible.
! Once this procedure is finished, replace the old rating sticker with one 
indicating the new type of gas used. Stickers are available from any of our 
Service Centres.
! Should the gas pressure used be different (or vary slightly) from the 
recommended pressure, a suitable pressure regulator must be fitted to the 
inlet pipe (in order to comply with current national regulations).
Electrical 
connections
DATA PLATE
see data plate
This appliance conforms to the following 
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low 
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments
- 93/68/EEC dated 22/07/93 and 
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and 
subsequent amendments.
- 2012/19/EC and subsequent 
amendments.