Hotpoint EG95 Benutzerhandbuch

Seite von 44
Installation – Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED.
Your cooker should have been checked to ensure that the voltage corresponds with your
supply voltage, this is stated on the rating plate, which is situated on the front of the plinth.
The cooker must be connected by a competent person eg. (NICEIC registered contractor)
to suitable double-pole control unit with a minimum rating of 30A and a minimum contact
clearance of 3mm, which should be fitted adjacent to the cooker, in accordance with latest
IEE regulations.
The power supply cable should conform to B.S.6004 with a conductor size of 6mm
2
.
This appliance conforms to EN 55014 regarding suppression of radio and television
interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp adjacent to the terminal block.
Sufficient cable should be used to allow the cooker to be pulled out for servicing.
Ensure that the mains cable is routed away from any brackets affixed to the rear panel and
is not trapped to the rear wall when pushing the cooker into position between cabinets. 
Your cooker is heavy, so it is advisable that two people move it The cooker is fitted with
rear wheels and will slide into position easily. Movement of your cooker is most easily
achieved as follows. Open the Grill/Oven door sufficiently to allow a comfortable grip on the
underside front edge of the oven roof, avoiding any grill elements or oven interior furniture,
and then lift and slide back at the same time.
Your cooker must stand on a flat surface so that the hob is perfectly level, and the cooker
is stable and cannot be rocked, this is easily achieved by adjusting the 3 feet which are
under the front of the cooker, if necessary.
The cooker is designed to fit between kitchen cabinets spaced 1000mm apart. The space
either side need only be sufficient to
allow withdrawal of the cooker for
servicing. It can be used with
cabinets one side or both. It can
also be used free-standing. 
This cooker is a class X appliance,
as such adjacent side walls which
project above hob level, must not
be nearer to the cooker than 65mm
and should be protected by heat
resistant material. Any overhanging
surface or cooker hood should not
be nearer 650mm.
4
Siting the Cooker
450mm
Min