Reservoir
The reservoir stores  hydraulic  system oil.  The breather cap which is mounted on top of the reservoir prevents
a pressure buildup or vacuum  from occurring in the tank  as oil level changes.  Their is also an oil filler cap
which is used to fill the reservoir with oil.  To help  prevent dirt  from entering the tank,  clean the top of the
reservoir before removing the cap.  THE BREATHER CAP HOLDS APPROX 11 PSI PRESSURE IN TANK.
REMOVE FILLER CAP SLOWLY
The oil level sight glass is located on the back of the reservoir.  The oil level should be even with the sight glass
and checked with the  cutter  unit  in the transport position. The oil temperature should not exceed 180 deg.F.
The oil return hoses are connected to the hydraulic filter on top of the reservoir.  Oil  is  returned from cutter unit
cooling tubes and filtered before entering the hydraulic reservoir.  Oil returning from the control  circuit  also
enters the reservoir thru the filter. Use Chevron 1000THF or an equivalent.
Note: Your ambient temperature and operating con ditions may require a different viscosity oil. Please consult
the oil manufacturer for proper specifications. 
Solenoid Control Valve
The solenoid control valve  directs oil flow  from the
hydraulic pump.  When the mower ON/OFF switch
is in the "ON" position,  the solenoid is energized
and the spool within the valve  is positioned to direct
oil to the cuttershaft motor.
When the mower ON/OFF switch  is in the "OFF"
position, oil pressure  within the valve pushes the
spool back which allows the oil to circulate through
the cutter unit before returning to the reservoir.
When the flow of oil to the motor is cut off, the
cuttershaft will stop rotating. Figure Mnt-FL-0017
Air Breather
Cap
Filler Cap
a. Control Valve
b. Solenoid