KitchenAid 9759121A Benutzerhandbuch

Seite von 28
10
4-Wire Cable from Power Supply
IMPORTANT: Use the 4-wire cable from power supply where 
local codes do not permit connecting the frame-ground 
conductor to the neutral (white) junction box wire.
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the 4-wire flexible cable from the range to the 
junction box using a UL listed or CSA approved conduit 
connector.
4. Tighten screws on conduit connector if present.
5. Connect the 2 black wires together using the UL listed wire 
connectors.
6. Connect the 2 white wires together using the UL listed wire 
connectors.
7. Connect the green or bare ground wire from the range cable 
to the green or bare grounded wire (in the junction box) using 
the UL listed wire connectors.
8. Install junction box cover.
9. Reconnect power.
3-Wire Cable from Power Supply
IMPORTANT: Use the 3-wire cable from power supply where 
local codes permit connecting the frame-ground conductor to 
the neutral (white) junction box wire (not used for Canadian 
installations).
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the 4-wire flexible cable from the range to the 
junction box using a UL listed or CSA approved conduit 
connector.
4. Tighten screws on conduit connector if present.
5. Connect the 2 black wires together using UL listed wire 
connectors.
6. Connect the 2 red wires together using UL listed wire 
connectors.
7. Connect the green (or bare) and white range cable wires to 
the white (neutral) wire in the junction box using UL listed 
wire connectors.
8. Install junction box cover.
9. Reconnect power.
Attach Backguard or Island Trim
1. Using 2 or more people, move range close to cabinet 
opening.
2. Remove cardboard or hardboard from under range. Move 
range into it’s final location.
3. Attach the backguard or island trim as required for your 
installation. See “Tools and Parts.” Attachment screws are 
included in the literature package.
A. Cable from power supply
B. Red wires
C. Green (or bare) ground wires
D. 4-wire flexible cable from range
E. Junction box
F. White wires
G. UL listed wire connectors
H. Black wires
I. UL listed or CSA approved 
conduit connector
A
B
C
D
E
F
G
H
I
A. Cable from power supply
B. Junction box
C. Red wires
D. White wire (from power supply)
E. Green (or bare) grounding wires 
(from range)
F. White wire (from range)
G. 4-wire flexible cable from 
range
H. Black wires
I. UL listed wire connectors
J. UL listed or CSA 
approved conduit 
connector
B
C
D
E
F
G
A
I
J
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.