INSTALLATION INSTRUCTIONS 
 
Install the ST-1 in the most convenient location for ease of cleaning, maintenance and general operation.  Avoid 
installing in locations with drafts, close proximity to grease or vapor-producing appliances or other high ambient 
heat equipment.  Allow approximately 1” clearance on sides and back of unit for proper air circulation.  Allow 
sufficient overhead clearance for proper heat dissipation.  This toaster must be level for proper operation and 
comes equipped with 1” adjustable legs for this purpose. 
 
Before operating this unit, be sure that the following two components are properly installed: 
 
1.  The reflector tray is installed below the lower heating elements before shipping.  It merely slides under the 
conveyor.  NOTE: Proper toasting cannot be performed without reflector tray installed. 
2.  The toast receiving tray is packaged separately and must be installed before operating this unit.  For front 
delivery position, slide the receiving tray into the toaster cavity below the control panel, making sure the 
lipped end is towards the back.  Place the lipped end over the two (2) protruding pins located at the rear of 
the toaster cavity.  For rear delivery position, slide the receiving tray into the cavity from the back of the 
toaster and place the lipped end over the 2 protruding pins closest to the front of the toaster (See Figure 1). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ELECTRICAL SPECIFICATIONS 
 
Voltage 
(Volts AC) 
Amperage 
(Amps) 
Max. Power 
(KW) 
Frequency 
(HZ) 
Phase 
Cord 
(Attached)
 
Plug 
(Attached)
 
120 14.8  1.7 50/60  1 
3’ 
NEMA 
5-15P 
208 12.5  2.4 50/60  1 
3’ 
NEMA 
6-15P 
220 9.6  2.1 50/60 1  3’ 
NEMA 
6-15P 
240 10.4  2.4 50/60  1 
3’ 
NEMA 
6-15P 
*220 
9.6 
2.1 
50/60 
3’ 
None 
*240 
10.4 
2.4 
50/60 
3’ 
None 
 
The circuit on which the receptacle is installed must be of adequate wiring size and sufficient capacity to meet the requirements 
indicated on the unit data plate and in accordance with the National Electrical Code and local electrical installation codes.  * The 
220V electrical information in the shaded area pertains to European models.  The 240V electrical information in the shaded area 
pertains to United Kingdom models. 
 
Use these two mounting pins 
for front delivery position. 
Toast receiving tray in 
rear delivery position. 
 
Toast receiving tray in 
front delivery position. 
 
This toaster must be plugged into the 
proper voltage which is specified on 
the data plate located on the back 
panel of the toaster.  Use of any 
other voltage or altering of plug will 
damage unit, void warranty and may 
cause injury. 
!