Low Profile – 1600 Advantage Series Service Manual – International 
 
 
 
 
 
 
 
 
replace the spark generator. If there  
 
 
 
 
 
 
 
 
is visible damage to the igniter/sensor  
 
 
 
 
 
 
 
 
assembly, replace. Also check for frayed 
 
 
 
 
 
 
 
 
or damaged wires in burner tube. 
 
 
 
 
Gas valve 
 
 
Check for supply voltage to gas valve. 
 
 
 
 
 
 
 
 
If there is no voltage present, check  
 
 
 
 
 
 
 
 
reset button, check all connections for 
 
 
 
 
 
 
 
 
tightness. If there still is no voltage at 
 
 
 
 
 
 
 
 
gas valve, replace ignition control. 
 
 
 
 
 
 
 
 
If there is voltage present, check for  
 
 
 
 
 
 
 
 
gas pressure at gas pressure tap located 
 
 
 
 
 
 
 
 
in gas piping at burner manifold. 
 
 
 
 
 
 
 
 
If there is no gas pressure, replace 
 
 
 
 
 
 
 
 
gas valve. 
Flame will not stay on   
Flame sensor   
 
To check for flame sensor operation, 
 
 
 
 
 
 
 
 
connect a digital multimeter (capable 
 
 
 
 
 
 
 
 
of measuring D.C. micro amps) in 
 
 
 
 
 
 
 
 
series with the flame sensor wire and 
 
 
 
 
 
 
 
 
ignition control. Sensor current is 3  
 
 
 
 
 
 
 
 
micro amps D.C. minimum.  
 
 
 
 
 
 
 
 
NOTE: The D.C. micro amp test must 
 
 
 
 
 
 
 
 
be conducted with the oven in low  
 
 
 
 
 
 
 
 
flame (bypass) operation. Turn the  
 
 
 
 
 
 
 
 
temperature control to its lowest  
 
 
 
 
 
 
 
 
setting. If these readings are not 
 
 
 
 
 
 
 
 
achieved, replace igniter/sensor assy. 
 
 
 
 
 
 
 
 
Also, check for any type of damage to 
 
 
 
 
 
 
 
 
flame sensor wire and connections. 
 
 
 
 
Ignition control   
 
If there is sufficient flame sensor current, 
 
 
 
 
 
 
 
 
but the burner will not remain ignited, 
 
 
 
 
 
 
 
 
check the reset button on ignition control. 
 
 
 
 
 
 
 
 
NOTE: Check for proper polarity of 
 
 
 
 
 
 
 
 
the power supply. If all of the above  
 
 
 
 
 
 
 
 
are OK, replace ignition control.  
Pilot lamp is on,  
 
Temperature control 
 
Check for supply voltage across 
But no main flame 
 
 
 
 
 
terminals L2 and 240 on temperature 
 
 
 
 
 
 
 
 
control board. If no voltage is present, 
 
 
 
 
 
 
 
 
check wiring back to hi-limit thermostat. 
 
 
 
 
 
 
 
 
Turn the temperature adjustment knob to 
 
 
 
 
 
 
 
 
the maximum temperature position and 
 
 
 
 
 
 
 
 
check for supply voltage at the load  
 
 
 
 
 
 
 
 
terminal #7 and #8. If voltage is present 
 
 
 
 
 
 
 
 
and unit is not heating, refer to  
 
 
 
 
 
 
 
 
“temperature regulation valve” for next 
 
 
 
 
 
 
 
 
check. If voltage is not present, proceed. 
 
 
 
 
Thermocouple probe 
 
With power on and thermocouple leads 
 
 
 
 
 
 
 
 
attached to board, measure the millivolt 
 
 
 
 
 
 
 
 
out put of the thermocouple. Refer to the 
 
 
 
 
 
 
 
 
thermocouple chart in section D for  
 
 
 
 
 
 
 
 
proper readings. 
 
 
 
 
Temperature control 
 
WITH POWER OFF: Remove the   
 
 
 
 
Potentiometer    
 
potentiometer leads from the temperature 
 
 
 
 
 
 
 
 
control board. Place ohm meter test leads 
 
 
 
 
 
 
 
 
on the blue and green pot leads. Reading  
 
 
 
 
 
 
 
 
should be 1 K ohms. Place meter leads  
 
 
 
 
 
 
 
 
across the blue and purple pot leads and 
 
 
 
 
 
 
 
 
rotate knob from high to low. Repeat on  
 
 
 
 
 
 
 
 
green and purple leads. Check for even  
 
 
 
 
 
 
 
 
rise and fall of ohms reading to insure  
 
 
 
 
 
 
 
 
that there are no open or dead spots in  
 
 
 
 
 
 
 
 
the potentiometer. Check each lead to  
 
 
 
 
 
 
 
 
ground for shorts. Replace potentiometer