1.
At least 31 square inches (200cm
 
)
1
2
  1 1/2
(38
mm
)
 2
3/4
(5
27
m
m
)
2
2
1
5
1/2" 
(13 mm)
24" 
(609.6 mm)
3-11/16" 
(93,7 mm)
The following ventilation cross-section and 
distances
 must be observed:
  -  There must be a ventilation space of at 
least 31 square inches (200 cm²) per 
appliance in the cabinet plinth and under 
the cabinet top panel.
  -  The depth of the ventilation duct at the 
rear of the cabinet must be at least 1-
1/2" (38 mm).
Alternatively:
1.   For built-in appliances without 
ventilation grilles and only with an 
installation frame, ventilation must take 
place through the ventilation duct at the 
rear of the cabinet.
Built-in appliances with an installation frame:
• 
Figure 19: 
  -  Screw the complete installation frame (2) 
to the appliance.
2.   Built-in appliances with a wooden 
ventilation grille:
 
Figure 20: Cut out the wooden trim for use 
as a ventilation grille using the enclosed 
template.
  -  The required ventilation cross-section 
must be at least 31 square inches 
(200 cm²) when a single appliance is 
installed, which corresponds to template 
“small” (If you install two appliances 
side-byside, the cross-section must be at 
least 62 square inches, (400 cm²), which 
corresponds to template “double-size;” 
for more information see “Side-by-Side 
Installation”).
• 
Remove the attachment bracket (2) from 
the installation frame and screw it to the 
appliance (1) from underneath. Place 
the wooden ventilation grille (5) on the 
appliance, align it in the center and secure 
it from the rear using the attachment 
bracket (2).
Figure 19