Temperature
Temperature (Factory set to 204 °F) 
Press  to Select. Press < or >  to move to desired temperature and then  to set. Temperature is programmable 
from 170ºF to 204ºF in 2-degree increments.
Energy Save Mode (Factory set to OFF)
 Press  to Select, < or  > ON, OFF or  ON 140ºF ,  to set. When in ON, unit will automatically shut off 4 hours 
from last brew. When feature is OFF, unit does not have the energy saving mode. 
 In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save 
energy by maintainig a lower temperature in the tank during periods of non-operation.
Energy Save Mode
Brew Count Total 
Press  to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to 5º F)
Press  to select,  < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set 
point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 
degrees of set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset 
Press  to display Are You Sure? 
Then  < for Yes,  > for No.
Brewer factory defaults are then reset.
Service Call (Phone number Factory set to [800] 995-0417) 
Press  to display number and change number or  < to move place and EX to exit when complete. This number 
will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4) 
Press  to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to 
exit when complete.
Banner Name (Factory set to WILBUR CURTIS)
Press  to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all 
blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)
Press  to Select, Set gallons brewed to indicate P-Maintenance. Press  < or > to adjust from Off to 3000 gallons. 
Press  to exit.
Beeper On/Off (Factory set to ON)
Press  to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature 
allows you to hear a short beep each time a button is pressed.
Model Select
Press  to Select. Display TCT G3 .
Master Reset
Service Call
Access Code
Banner Name
P-Maintenance
Brew Count Total
Cold Brew Lock
Beeper On/Off
Exit
Exit
Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
Brew Count Odom. 
Press  to display total brew cycles. Press ex or Reset
Brew Count Odom
PROGRAM MENUS CONTINUED
Model Select
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold   3   button (see illustration, page 2) for 5 seconds.  Water Temperature will 
be displayed (temperature in heating tank). 
3