Wiring Diagram #091-182
T3
T3
T3
1
1
T4
A
T2
T3
T3
T4
T4
T4
B
T2
T3
T3
1
1
T1
C
T3
T3
T3
T1
T1
T4
D
T2
T3
T3
T1
T1
T4
E
T2
T3
T3
T1
T1
T2
F
NOTE: USE WIRE NUT FOR 1  -  1 CONNECTION
5000 WATT / 240V HEATERS
* SEPARATE 120V REQUIRED FOR CONTROLS (3 AMP LOAD)
2.0 KW - 120/208V - 1 PH - 3 WIRE - 9 AMPS
2.5 KW - 120/240V - 1 PH - 3 WIRE - 11 AMPS
4.0 KW - 120/208V - 1 PH - 3 WIRE - 18 AMPS
5.0 KW - 120/240V - 1 PH - 3 WIRE - 21 AMPS
5.5 KW - 120/208V - 1 PH - 3 WIRE - 27 AMPS
7.5 KW - 120/240V - 1 PH - 3 WIRE - 31 AMPS
7.5 KW - 120/208V - 1 PH - 3 WIRE - 38 AMPS
10.0 KW - 120/240V - 1 PH - 3 WIRE - 42 AMPS
11.5 KW - 120/208V - 1 PH - 3 WIRE - 54 AMPS
15.0 KW - 120/240V - 1 PH - 3 WIRE - 63 AMPS
11.5 KW - 120/208V - 3 PH - 4 WIRE - 31 AMPS
15.0 KW - 240V - 3 PH - 3 WIRE - 36 AMPS *
A
B
C
D
E
F
WIRE PER FIG.
FOR THIS HEAT AND ELECTRIC SERVICE
* FOR 3 PHASE WIRING
1. MOVE WIRE  6  FROM L1 TO L3
2. CONNECT HEATER ACCORDING TO FIG. F 
ON CHART
3. FIG. F FOR 3 PH ONLY
WIRES  5  6  7  8  ARE 8 AWG, 105°C
1  2  3  4  ARE 10 AWG, 105°C
A
Page 32
Shuttle Brewers & Airpot/Shuttle Brewers