Bunn LCA-1 Benutzerhandbuch

Seite von 23
12
Displays Software Version # -
Exits To Home View After 3 Seconds.
PROGRAMMING THE DISPENSER
Two basic modes are available to the operator: Display Mode and Program Mode. Open the dispenser door to 
access the digital Programming Switches with LED display. To enter the Display Mode, Set the RUN/NIGHT/
PROGRAM Switch to the RUN position.
Display Mode: Used to view the current set-up values. Use the MENU switch to scroll to the next display.
NOTE: The display blanks out after two minutes of inactivity. Press any button to activate the display.
 
LED DISPLAY 
 DISPLAY MODE 
 DESCRIPTION
Home View
LCR-1 Alternates between the Tank and 
Cabinet Temp.
LCA-1 Displays Tank Temp only.
Tank Temperature
Displays Target Tank Temperature (F°)
Dispense Ratio
Displays Dispense Ratio (XXX:1)
Portion Volume
Displays Portion Dispense Volume 
(XX.X Oz.).
Set to 0.0 to Disable.
Dispense Total
Displays Total Coffee Concentrate 
Dispensed (XX.X Gal)
Rinse Alarm (Hrs)
Displays The Number Of Hours 
Between Required Rinses.
(Default = OFF, Alarm Disabled)
MENU
(-)
(+)
1 8 0
MENU
(-)
(+)
0 1 8 0
MENU
(-)
(+)
0
3
1
MENU
(-)
(+)
3 0.0
MENU
(-)
(+)
O
4
F F
MENU
(-)
(+)
0
2 0.
Software Version
MENU
(-)
(+)
XX.X
44806.1 081211