SERVICE (cont.)
INLET VALVES 
Location:
 
The solenoid valve(s) are located inside the trunk 
on the lower center part of the component bracket. So-
lenoids in the early models are located in the hood.
Test Procedures:
1.  Check the solenoid valve for coil action. With "ON/
OFF" switch in the "ON' upper position press start 
switch and listen carefully in the vicinity of the 
solenoid valve for a" clicking" sound  as the coil 
magnet attracts.
2.  Disconnect the brewer from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If the sound is not heard as described,  proceed to 
#3.
3.   Disconnect the brewer from the power source.
4.  Connect a voltmeter across the solenoid terminals 
(leave wires connected).
5.  Connect the brewer to the power source. With the 
"ON/OFF" switch in the "ON" upper position press 
the start switch.
6.  Check the voltage across the solenoid. The indica-
tion must be:
 
a) 120 volts ac for two wire 120 volt models and 
three wire 120/240 volt models.
 
b) 200 to 230 volts ac for two wire 200 or 230 volt 
models.
7.  Disconnect the brewer from the power source,
If voltage is present as described, proceed to #8
If voltage is not present as described, refer to Wiring 
Diagrams and check brewer wiring harness.
8.  Check for continuity across the solenoid termi-
nals.
If continuity is present as described, reconnect the 
white and black wire from the timer.
If continuity is not present as described, replace the 
solenoid valve.
Removal and Replacement:
1.   Disconnect the brewer from the power source.
2.  Turn off the water supply to the brewer.
3.  Remove the wires from the solenoid.
4.  Disconnect the water lines to and from the solenoid 
valve.
5.  Remove  the  two  screws  securing  the  solenoid 
mounting bracket to the component bracket. 
6.  Install  new  solenoid  valve  to  the  component 
bracket.
7.  Securely fasten the water lines to and from the 
solenoid valve.
8.  Refer  to  schematics  when  reconnecting  the 
wires.
FIG. 17-1 INLET VALVES