GROUNDING 
INSTRUCTIONS
This stove is for use on 120 volts. The cord has a 
plug as shown in Figure 2. An adapter is available 
for connecting three-blade grounding-type plugs 
to two-slot receptacles. The green grounding lug 
extending from the adapter must be connected to 
a permanent ground such as a properly grounded 
outlet box. The adapter should not be used if a 
three-slot grounded receptacle is available.
Figure 2 - Grounding Methods
Figure 3 - Electric Stove Control Panel
OPERATING 
INSTRUCTIONS
Once the unit has been properly connected to a 
ground electrical outlet, it is ready to operate.
Note:
 Ensure the circuit breakers for power 
supply are turned on. 
CONTROL PANEL OPERATION
Controls are located on the back of the unit 
(see Figure 3).
1.  Main ON/OFF power switch: This switch is 
located at the furthest right corner on the 
control panel when looking at the back of 
the unit. Turn the switch to ON and unit 
will be ready to operate. The "|" indicates 
ON and "O" indicates OFF. 
2.  Heater  Switch  and  Control  Dial:   The 
heater switch has a sun directly below it. To 
turn the heater on, flip the Heater Switch 
to ON position (the "|" indicates ON and 
"O" indicates OFF). The Control Knob 
has a thermometer below it. Turn the dial 
clockwise past the number 8. You should 
hear a small clicking sound indicating the 
heater has started and heat will emit the 
from the vents at the top of the unit. To 
turn off heater, turn the temperature dial 
counter clockwise past number 1 and flip 
the Heater Switch to OFF position. 
   To increase the desired temperature, turn 
the  temperature  dial  clockwise  towards 
Number 8.
 
To decrease the desired temperature, turn the 
temperature dial counter clockwise towards 
number 1. The heater has a built-in thermo-
stat so it will shut off automatically once the 
set temperature is reached. It will also turn on 
automatically if the room temperature drops 
below the set temperature on the dial.
 
Note:
 When the heater is turned on for the 
first time, it may release a slight, harmless 
odor. This odor is a normal occurrence caused 
by the initial heating of the internal heating 
elements and should not occur again.
4.  Flame Control Dial: This dial controls the 
intensity of the flame.
Light Adjustment 
Dial
Main Power Switch
Flame 
Control Dial
Heater 
Switch
Heat Control 
Dial
Grounding Pin
Adapter
CLEANING AND 
MAINTENANCE
  WARNING: Always  discon-
nect power and allow the heater 
to  cool  before  performing  any 
cleaning, maintenance or reloca-
tion of this heater. Turn controls 
to  OFF  and  remove  plug  from 
outlet or turn off circuit breaker 
to heater.
Turn off heater and circuit breaker to heater before 
performing any cleaning and/or maintenance. Al-
low heater to cool completely.
BULB REPLACEMENT
 WARNING: The halogen light 
bulbs  in  your  unit  can  become 
extremely hot. Allow at least 10 
minutes between turning off the 
heater  and  removing  the  light 
bulbs to avoid accidental burns.