Checking the Rotational Direction 
Rotational direction of the motors must be checked before initial start-up.  The following 
steps must be completed. 
1.  Switch the machine ON and then immediately OFF again. 
2.  Observe whether the discharge air fan in the drive motor is rotating in the 
direction of the direction arrow. 
NOTE:  If running in the wrong direction, reconnect the motor connection 
immediately.  Damage to the machine will result from operation in the wrong direction. 
 
 
3-3  Initial Start-up  
 
General Advice 
•  All work related to start-up may only be carried out by trained and specialized 
personnel. 
•  Check the machine for possible transportation damage or other damage.  If any 
damage exists, confirm it with the freight company and report it to the manufacturer. 
•  After setting up for service and before starting up for the first time, necessary checks 
must be completed. 
•  Check the oil level of the gear box before operating the machine. 
•  Fill oil into the hydraulic tank. 
•  Please observe the operation manual from the manufacturer
 
Machine Check Prior to Start-up 
9  Use a torque wrench to check the cutter mounting screws when lower housing flap is 
open. 
9  Search the grinding chamber for foreign matter. 
9  Open the lower housing flap and make sure the screen has been inserted in 
accordance with the regulations. 
9  Close upper housing flap and fasten screws tightly. 
9  Check oil level of the gear box. 
9  Fill oil into the hydraulic unit. 
9  Examine in-feed device (accessories) for foreign matter. 
9  Check that the Emergency Stop buttons are unlocked. 
9  Check all safety devices for proper functioning.