DELL Version 5.3 Benutzerhandbuch

Seite von 500
314
Resource Monitors | Monitoring
4
Select an entity to monitor by clicking the Add button in the top portion of the Monitor 
Options screen. 
5
Select devices you want to ping, (Ctrl+click to add more than one), then click Add Selection 
then Done to confirm your entity.
6
Define packets in the ICMP Monitor Options panel, including Packet Size, Packet Count and 
timeout. You can accept the defaults here, too.
7
In the Thresholds tab, select an attribute (MaxRTT, or maximum round trip time) and add 
the following thresholds by clicking Add:
Name High color red, Lower Boundary 15 and Upper Boundary [blank] Severity Critical 
Name Fine color green, Lower Boundary 0 and Upper Boundary 15 Severity Cleared
Notice that this example does not emit a notification. If you checked that checkbox, an alarm 
of the configured severity would accompany crossing the threshold. 
8
Accept the other defaults and click Apply
9
Click Save.
10
Test ICMP Monitor now appears in the portlet.
11
12
How To:
Create a Monitor Report
You can create reports based on your monitors. The following example creates a report based on 
1
Create a new Report Template by right-clicking the Report Templates portlet, selecting New 
> Table Template.
2
Name the report (here: Test SNMP Interface Report).
3
Select a source in the Source tab. Here: Active Monitoring > SNMP Interfaces.
4
Notice that the Select your inventory columns panel displays the attributes available based on 
your monitor selection.
5
Select Available columns and click the right arrow to move them to Selected. In this case we 
select SNMP Interfaces: Monitor Target, Polled Date / Time, ifInErrors.
6
Arrange the columns and fonts as you like in the Layout tab.
7
Save the template.
8
Right-click, and select New in the Reports portlet.
9
Enter a Name and Title for the report.