CONTROLLER FEATURES
Fahrenheit or Celsius Temperature Display
The operator will have the ability to configure the controller to display the temperature in degrees
Fahrenheit or Celsius from the System Programming mode. 
Melt Cycle
When the computer is ON and the vat temperature is below the Melt Limit Temperature, the controller
will control the melting of the shortening. 
Programmable Times
The operator will have the ability to program the cook times for each product key. The controller is pro-
grammable in minutes (up to 59) and seconds (up to 59). 
Programmable Temperatures
The operator will be able to program cook temperatures for each product key. The valid temperature
range is 250 to 390°F (121 to 199°C). 
Programmable (FASTFLEX.)
TM
Timing Mode
The operator will be able to program the timing mode (flex or straight) for each product key. If a prod-
uct is configured for flex time, the controller will adjust the actual cook time taking into consideration the
temperature variation due to load size, initial product temperature, product moisture content, and other
factors affecting the cook cycle, to insure the controller provides consistent, high-quality product. Under
straight time mode, the controller will cook only for the specified time without adjusting for these vari-
ations. 
Programmable Action Alarms
The operator will be able to program one  action alarm on each product key. An action alarm is an indica-
tion to the operator to perform some action at a pre-programmed time.