Henny Penny 341 Benutzerhandbuch

Seite von 3
 Model OFE/OFG/OEA/OGA-341, 342 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5-1.    TROUBLE SHOOTING GUIDE 
 
 
Problem Cause  Correction 
 
POWER switch ON but fryer 
•  Open circuit 
•  Plug fryer in 
completely inoperative  
   
 
   
   
•  Check breaker or fuse at supply  
  
  
 box
 
 
Shortening will not 
•  Open high limit 
   
•  Reset high limit per 
heat but lights are on. 
  circuit 
   
  High Limit Temperature 
 
 
  Error message “E10” 
  
 Control Section 
 
 
 
  •  Drain valve open 
   
•  Turn drain valve handle to  
 
 
  Error message “E15” 
  
 closed position 
 
 
Foaming or boiling 
  •  Water in shortening     
•  At end of Cook Cycle, drain  
over of shortening 
   
  
 shortening and clean 
 
 
   
 
 
  •  Improper or bad 
   
•  Use recommended shortening 
 
 
  shortening 
 
 
 
  •  Improper filtering 
   
•  Refer to the procedure covering  
 
 
   
  
 filtering the shortening 
 
 
 
  •  Improper rinsing after   
•  Clean and rinse the frypot, then  
 
 
  cleaning the fryer    
 dry thoroughly 
 
 
      
 
Shortening will not 
  •  Drain valve clogged     
•  Open valve, force cleaning  
drain from frypot 
    with crumbs 
   
  brush through drain 
 
Filter switch on, 
  •  Motor thermal 
   
•  Reset thermal switch per section 
motor does not run 
    protector tripped 
   
  on Filter Pump Motor 
 
 
   
  
 Protector – Manual Reset 
 
 
 
 
More detailed troubleshooting information is available in the Technical Manual, available at  
 
www.hennypenny.com, or 1-800-417-8405 or 1-937-456-8405.   
 
 
903                                                                                                                                                                          5-1
 