F18 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
6
Delfield
®
CAUTION
Operation
After turning the ON/OFF switch to ON the unit’s compressor 
will begin operating. Delfield refrigerated bases are designed 
to maintain an operational temperature of 36°F to 40°F. 
Temperature in the salad top and refrigerated rail opening is 
33°F to 41°F with pans recessed 3” on a standard wrapped 
refrigerated rail or flush with the LiquiTec option at 86°F 
ambient room temperature. Freezer bases are designed to 
maintain an operational temperature of 0°F.
Do not place hot pans on/against the blue ABS 
liner. Do not throw items into the storage area. 
Failure to heed these recommendations could 
result in damage to the interior of the cabinet or 
to the blower coil.
Overloading the storage area, restricting the air flow, and 
continuous opening and closing of the doors and drawers 
will hamper the units ability to maintain operational 
temperature.
Refrigerated rail units
Product in the rail should be removed to the refrigerated base 
at the end of the day. This allows you to turn the 
rail off at night to save energy and the rail will have 
time to defrost as needed. It also helps maintain 
product quality.  The standard wrapped refrigerated 
units are controlled by the pressure control which 
is set to maintain the proper rail temperature an on/off switch 
is also provided for the rail and is required to be shut off at 
night.  The rail switch shuts off the rail only.  With a LiquiTec 
rail a thermostat is provided to maintain rail temperature as 
well as the rail on/off switch.  The LiquiTec rail is required to 
be shut off at night as well to allow for defrosting.  To ensure 
product quality in the rail it is recommended that product be 
rotated every four hours.
If adding any item to the unit, be sure to keep 
in mind the location of the refrigeration lines on 
wrapped rail units.  A refrigeration leak in a rail 
is extremely difficult and costly to repair.  In some 
cases it cannot be repaired at all.
Installation
Location
Be sure the location chosen has a floor strong enough to 
support the total weight of the cabinet and contents. A 
fully loaded 72” long model may weigh as much as 1500 
pounds! Reinforce the floor as necessary to provide for 
maximum loading.
It is very important to allow for proper air flow, both 
inside and outside.
Avoid hot corners and locations near stoves, ovens and 
other pieces of cooking equipment.
It is recommended that the unit be installed 
no closer than 1” from any wall. Do not install 
the unit near any combustible material or 
object affected by heat or moisture.
Leveling
A level cabinet looks better and will perform better 
because the drain pan will drain properly, the doors will 
line up with the frames properly, and the cabinet will not 
be subject to undue strain.
A unit on legs will have an adjustable bullet foot on each 
leg, adjust each for a level unit.  A unit on casters will not 
be adjustable.  Be sure the unit is on a level floor, make 
necessary changes to the floor for proper level.
Lock all front casters to ensure the stability of the unit.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If, for some reason a unit does not have a 
condensate evaporator, or if the evaporator fails, the unit’s 
drain must have an outlet to an appropriate drainage area or 
container.  A refrigerated rail will have a 1" drain which will 
need to be run to an appropriate floor drain or container.  
The drain will be stubbed to the bottom of the machine 
compartment.  Either run drain to a floor drain or add a valve 
to the base of the machine compartment and drain the rail to a 
container when convenient.  The LiquiTec option will NOT have 
a drain available.
Moisture collecting from improper drainage can 
create a slippery surface on the floor and a hazard 
to employees. It is the owner’s and operator’s 
responsibility to provide a container or outlet for 
drainage.
Electrical connection
Refer to the amperage data on pages 3-5, the serial tag, your 
local code or the National Electrical Code to be sure the unit is 
connected to the proper power source. A protected circuit of 
the correct voltage and amperage must be run for connection 
of the line cord, or permanent connection of the unit.
Self-contained units with a cord and plug have an ON/OFF 
switch located directly behind the louvered panel covering 
the compressor section. Simply turn the switch to ON to 
begin operation.
The power switch must be turned to OFF and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
Never operate the unit without the louvered panel 
in place!
If electrical receptacles are to be mounted in the unit’s 
backsplash, they must be wired independently from the 
existing unit wiring.