IA-MKDL-300-CC
 
Make sure kettle is level, equipment can move as floors settle
  Make sure kettle is bolted securely to floor, bolts may loosen after
time
  Check the incoming power and amp draws (per rating plate)
  Check incoming air pressure (_” line 1cfm @ 90psi.)
  Check air pressure regulator/collector for draw off valve (45psi.)
  Check air pressure regulator for kettle jacket purge (15psi.)
  Check air collector regulator for moister, dirt (Must be clean & dry)
  Check all o-rings and shaft seal for wear and proper lubrication
  Check the installation 3” Flush Piston Draw Off Valve
  Check all air hoses for leaks and signs of wear
  Check incoming steam pressure (3/4”line / 320PPM / 65psi.)
  Check the steam trap for proper operation (clean or replace if
needed)
  Check the operation of safety valve 100psi. rating
  Check for steam leaks (Inlets and Returns)
  Check for the proper clearance where drive shaft penetrates the
kettle
  Make sure temperature sensor is properly installed
  Check chill water supply and return lines for leaks.
  Check the control panel for any signs of corrosion moisture
  Check the complete operation of all kettle controls
  Check the mixer operation (Speed control, Emergency stop)
  Check the idler bearing and idler busing for wear
  Check the kettle tilt (up and down)
  Check hydraulic fluid level
  Check hydraulic lines for leaks and signs of wear
  Change hydraulic fluid yearly (ISO 46 20 weight Food Grade)
  Grease tilt mechanism  monthly (Food grade grease)
  Check the operation of 3” Flush Piston Draw Off Valve
  Check water meter operation
  Make sure the Partlow chart recorder/controller is (controlling,
reading, and charting correctly)
  Check the cooking operation in both automatic and in manual modes
  Check the operation of gentle heat mode
  Check the operation of the chill mode
  Check kettle cover hinge tension and fasteners